Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberBLD11-01708
StatusFinaled
Name JSE ENTERPRISES LLC
Site Address 6900 W TARGEE ST
Project NameGILLINGHAM BUILDING
Customer Number 
ePlanReviewNo
Description
(GILLINGHAM BUILDING) This building will NOT have a fire sprinkler system. To construct a new 5,280 square foot office (880 square feet) and garage (4,400 square feet) building. Concrete work is to include concrete footings, concrete foundations, and concrete slabs on grade. According to the Geotechnical Investigation, this site has undocumented fill that may extend up to 45 feet below the footings of the new building. The existing material below where the spread footings will be located is required to be removed to a depth of at least 2 feet below the bottom of the proposed spread footings and replaced with structural fill. This work and all other site work is required to comply with the approved Geotechnical Investigation report (7-8-11) and letter (8-8-11) prepared by the Geotechnical Engineer. Special Inspections include concrete and soils. Inspections by the Geotechnical Engineer are also required. The above grade work includes 2x6 wood stud exterior walls, OSB wall sheathing, metal siding, cultured stone veneer, lap siding, engineered wood roof trusses, OSB roof sheathing, metal roofing, interior nonbearing walls, interior doors, exterior side-hinged swinging doors, roll-up exterior doors, 2 restrooms accessible to the disabled, and interior finishes. The interior side walls and ceilings will have 5/8 inch gypsum wallboard installed. The work is required to comply with the approved drawings, with the Geotechnical Investigation report, with the structural calculations, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/4/201111/7/201111/7/2011PPASS
DetailsTom Arcoraci
Jeff Phone #: ###-####
FIRE-Final Inspection11/3/201111/4/201111/3/2011APASS
DetailsTroy Cobbley
life safety passed
FIRE-Final Inspection11/2/201111/3/201111/3/2011AFAIL
DetailsTroy Cobbley
Provide fire dept access signage as discussed and provide single action hardware on the office and restrooms doors.
BLD-Energy code compliance10/18/201110/19/201110/19/2011PPASS
DetailsTom Arcoraci
LATE AFTERNOON--JEFF Phone #: ###-####
BLD-Framing/Rough-in10/17/201110/18/201110/18/2011PPASS
DetailsTom Arcoraci
jeff Phone #: ###-####
BLD-Other10/6/201110/7/201110/7/2011PPASS
DetailsTom Arcoraci
Shear sheet & hold down--Jeff Phone #: ###-####
BLD-Foundation9/14/20119/15/20119/15/2011ADEFR
DetailsMike Jordan
Jeff-Concrete pour at 12:00 noon Phone #: ###-####
BLD-Footing9/13/20119/14/20119/14/2011APASS
DetailsMike Jordan
jeff - as early as possible please Phone #: ###-####. Perimeter footings for shop and office. Will kave special inspections. Aslo reviewed special inspection reports to date. All footings have been over excavated, backfillled, compacted and tested per special inspection report. Geo-tech. engineer has also inspected and approved footings per his report.