Permit Information
Permit NumberBLD11-01934
StatusFinaled
Name HCD INC
Site Address 8083 W FAIRVIEW AVE
Project NameKIM'S KARE-A-LOT
Customer Number 
ePlanReviewNo
Description
(KIM'S KARE-A-LOT) New daycare tenant in existing 5,310 sq. ft. space within existing strip mall shopping center. Work to include select non-structural demolition; construction of a 2-hour fire-resistive Fire Wall to divide existing building for compliance with allowable area; modify front exterior wall and overhang projection to be 1-hour fire resistive construction with 3/4 hour rated windows, doors and hardware in the front wall on both sides of fire wall for the depth of the projection (approx. 10'); remove indicated interior windows and replace with safety glass; modify all interior doors & openings to provide 32" clear width; lever hardware on interior doors. This tenant space will be separated on north side from other tenants with newly constructed 2-hour fire wall. NOTE: This building is fully fire sprinklered for area increase. drs CUP11-00035 X-REF CUP10-00017
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/27/20122/27/20122/27/2012PPASS
DetailsMike Jordan
Junior Phone #: ###-####. ok for perm occ.
BLD-Aging Inspection1/23/20121/23/20121/25/2012 DONE
DetailsMike Jordan
Spoke to Junior with HCD, he noted that rated glazing should be here by the end of Jan 2012.
BLD-Final11/21/201111/22/201111/22/2011APART
DetailsMike Jordan
Please call 30 min before thanks Phone #: ###-#### >> Inspection requested via web by Les Seal. Ok for temp occ. only. Will be ok for perm occ. once plumbing is perm. and firerated glazing is installed in place of temp. 1hr. wall.
BLD-Final11/21/201111/21/201111/21/2011PNR
DetailsMike Jordan
junior Phone #: ###-####
FIRE-Final Inspection11/21/201111/21/201111/21/2011PPASS
DetailsTroy Cobbley
life safety passed.
BLD-Conference11/18/201111/18/201111/18/2011PDONE
DetailsMike Jordan
junior Phone #: ###-####
FIRE-Conference11/17/201111/17/201111/17/2011PDONE
DetailsTroy Cobbley
For a final on this project we need to test the smoke alarms, exit signs/emergency lights, and verify hardware.
BLD-Final11/14/201111/14/201111/14/2011PCANC
DetailsMike Jordan
Please call junior 30 min before Phone #: ###-#### >> Inspection requested via web by Les Seal. Cancelled by contractor via phone call.
FIRE-Conference11/14/201111/14/201111/14/2011ADONE
DetailsTroy Cobbley
I went over life safety notes with JR.
BLD-Framing/Rough-in11/1/201111/1/201111/1/2011PPASS
DetailsMike Jordan
junior - late afternoon please Phone #: ###-####. double layer 5/8 type x at canopy lid ok.
BLD-Wall cover11/1/201111/1/201111/1/2011APASS
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Les Seal. Structural beam in canopy wrap with 5/8 type x rock, 2 layers ok.
BLD-Wall cover10/24/201110/25/201110/25/2011APASS
DetailsMike Jordan
Please call junior 30 min before thanks Phone #: ###-#### >> Inspection requested via web by Les Seal
BLD-Conference10/24/201110/25/201110/25/2011ADONE
DetailsMike Jordan
Please call junior 30 min before thanks Phone #: ###-#### >> Inspection requested via web by Les Seal. Conferance on canopy protection.
BLD-Framing/Rough-in10/19/201110/20/201110/20/2011APASS
DetailsJim Storey
Dennis-dry wall inspection Phone #: ###-#### gyp ok/ col rapped and ok to continue 2nd layer on north side. roof framing ok to cover glb still needs 48" gyp wrap and 2x4 removed from 2 hr wall penatrations will need fire stopped.