Permit Information
Permit NumberBLD11-02589
StatusFinaled
Name YICK YEE FAMILY CO
Site Address 8001 W FAIRVIEW AVE
Project NameHAPPY LAND CLUB & CULTURE
Customer Number 
ePlanReviewNo
Description
(HAPPY LAND CLUB & CULTURE) Remodel changing occupancy from retail to an assembly use within an existing 5,040 sq. ft. building per approved plans. Work to repair and remodel of existing open space for use as assembly occupancy for Social and cultural club. Specifically notified that recent adopted ordinance of Boise City prohibits any smoking in this type of establishmnet. Lighting and mechanical have been upgraded as necessary to provide acceptable compliance with energy code and ventilation requirements. Emergency lighting required within assembly space and at the exterior exit landings if not existing. Door hardware to be panic hardware for exits serving the assembly area (see code for exception). install mechanical init for additional outside air compliance and energy recovery compliance. No strcutural modifications under this permit. Add additional plumbing fixture per chanpter 29 for additional womens water closet and hi-lo drinking fountain and accessible route to and within the restrooms and adjoining areas. This building is not sprinklered. Post a maximum occupant load sign od 216 adjacent to main exit door on the interior. Planning approval done under CUP11-00062.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/11/20127/12/20127/12/2012PPASS
DetailsMike Jordan
Panic hardware installed. Ok for perm occ.
BLD-Final7/9/20127/11/20127/11/2012PNR
DetailsMike Jordan
james Phone #: ###-####. Waiting for panic hardware on front door, on order. All other issues hace been resolved.
BLD-Final7/10/20127/10/20127/10/2012PFAIL
DetailsMike Jordan
Still needs to remove locking device from rear door and provide panic hardware at main entry door. All other issues hace been resolved. Issued 48 hour notice to have remaining issues repaired.
BLD-Final7/2/20127/9/20127/9/2012PFAIL
DetailsMike Jordan
Talk to Jim Sly. Needs to install grab bars and correct door hardware at main entry, back door and womens restroom. Needs to be repaired by 7-10-12 or a 48 hr. notice will be issiued.
BLD-Final6/29/20127/2/20127/2/2012ADEFR
DetailsJim Sly
James Phone #: ###-####
Extend Permit 7days.....Re-insp Mon 9th PM
BLD-Final6/1/20126/1/20126/1/2012PPART
DetailsMike Jordan
Colton Phone #: ###-####. Ok to extend temp occ for 30 days. Mech. permit has been pulled.
BLD-Conference5/18/20125/21/20125/21/2012ADONE
DetailsMike Jordan
Nees to pull permit for mechanical work done and get inspected. Will give 30 day extension after this has been completed.
BLD-Conference5/17/20125/18/20125/18/2012PPASS
DetailsMike Jordan
steve call for access Phone #: ###-####
BLD-Framing/Rough-in3/26/20123/27/20123/27/2012PNR
DetailsDave Hannah
adnan Phone #: ###-#### needs rough ins first they have changed the wall layout by two feet this will give them two full wemans rest room ok to put high low drinking fountain on wall in area between two wemans resroom
BLD-Final3/6/20123/7/20123/6/2012APART
DetailsMike Jordan
Ok for temp occ as per letter from building official on file.
BLD-Conference2/28/20122/29/20122/29/2012ADONE
DetailsMike Jordan
adnan Phone #: ###-####
FIRE-Final Inspection2/27/20122/27/20122/27/2012PPASS
DetailsForrest France
Correction items finished with the exception of single motion hardware at the back storage exit door. Lever set has been installed but does not meet a fail safe condition- tenant to provide approved style hardware at this location prior to structural final as agreed.
FIRE-Final Inspection1/25/20121/26/20121/26/2012AFAIL
DetailsTroy Cobbley
See redline notes on plans for deficiencies. They include providing a code compliant address, mounting and tagging the fire extinguishers, providing panic hardware at the main exit and providing single action hardware on the rear Storage exit door and remobing the 2x6 dead bolt/bar. There is an existing basic fire alarm system that consists of two manual pull stations and one horn. Per Scott Arellano its existance is to be noted and is ok to remain.