Permit Number | BLD12-00165 |
Status | Finaled |
Name |
HC COMPANY INC
|
Site Address |
11311 W CHINDEN BLVD
|
Project Name | RACKING-HP BLD 7 TEST LAB EXPA |
Customer Number | |
ePlanReview | No |
Description |
RACKING-HP BLD 7 TEST LAB EXPANSION- To relocate 240 sq.ft. of existing steel storage racks within the HP Complex. Install steel rack shelving in accordance with engineering, within the Package Test Lab created as indicated under BLD11-02973. Engineered maximum load per beam shelf is called out at 2,000# per shelf, maximum 2 shelves between vertical rack columns. One anchor per base plate. Anchor to be 1/2" Hilti Kwik Bolt TZ with minimum 3-1/2" embed, ESR-1917 copy attached. Special inspection is required. See attached Statement of Special Inspections. Rack storage to be maximum 12 ' or less in height. A seperate fire protection permit will be required for any modifications necessary to the existing fire sprinkler system. The existing fire sprinkler system shall be evaluated by a licensed fire sprinkler contractor for compliance. *drs*
|