Permit Number | BLD12-00222 |
Status | Finaled |
Name |
HC COMPANY INC
|
Site Address |
11311 W CHINDEN BLVD
|
Project Name | HP - BLDG 7 |
Customer Number | |
ePlanReview | No |
Description |
(HEWLETT PACKARD)(BLDG 7 CSTL - RACKING) Install 3, 3' x 10', high pile, steel storage racks within new 1260 sq. ft. chain-link fenced area per reviewed plans and engineering design calcs and details. Hilti Kwik Bolt TZ anchors (ESR-1917) are called out to anchor racks, 2 per base plate at diagonal corners W/ 3-1/2" min. embed. Gate to fenced storage area shall have door hardware in compliance with Section 1008.1.9 & 1008.2. Letter attached from sprinkler contractor to fire department plan review stating Treasure Valley Fire Protection is under contract to install sprinklers as required for coverage at new racks and surrounding area. Separate application, plan & permit required before any modification to sprinkler or alarm systems as regulated by the fire department. drs
|