Permit Information
Permit NumberBLD12-00682
StatusFinaled
Name TRILOGY DEVELOPMENT INC
Site Address 1405 S GOLDKING WAY
Project NameUnion Square Apartments Bld 9
Customer Number 
ePlanReviewNo
Description
(Union Square Apartments, BLD - 9) To construct a wood frame, three story, 15,924 sq. ft., 18 Unit Multi Family Dwellings (6-2B/2B) (12-1B/1B), per reviewed plans. All units exceed 800 sq. ft., are fully sprinklered W/ alarm. Work includes associated site work, footing & foundation, structural & non-structural framing; electrical, mechanical, plumbing, sprinkler & alarm work; fire-resistive construction between units, at stair enclosures or rated corridor breezeways; accessible Type 'B' units; interior cabinetry, wall, floor and ceiling finishes and fixtures. All per the reviewed plans. drs DRH12-00022 CUP08-00045
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection5/24/20135/24/20135/24/2013 PASS
DetailsMike Jordan
BLD-Final3/5/20133/5/20133/5/2013PPASS
DetailsMike Jordan
will be ok for perm occ. once zoning signs perm.
BLD-Final3/4/20133/5/20133/5/2013APEND
DetailsTom Arcoraci
michael Phone #: ###-#### sent to 450 for pm insp
BLD-Final2/28/20132/28/20132/28/2013PPART
DetailsMike Jordan
Michael Phone #: ###-####. Ok for temp occ. Needs to complete minor firecaulking on plumbing fixtures.
FIRE-Final Inspection2/27/20132/28/20132/28/2013APASS
DetailsTroy Cobbley
Life safety passed
BLD-Conference2/25/20132/25/20132/25/2013PDONE
DetailsMike Jordan
Michael Phone #: ###-####
BLD-Other11/2/201211/5/201211/5/2012PPASS
DetailsTom Arcoraci
BLD-Other11/2/201211/2/201211/2/2012PPASS
DetailsMike Jordan
Interior shear walls, 1st. flor base layer on horizontal assemblies, face layers at 2nd floor horizontal assemblies.
BLD-Energy code compliance10/29/201210/29/201210/29/2012PPASS
DetailsTom Arcoraci
Phone #: ###-#### >> Inspection requested via web by Kelly Perryman
BLD-Framing/Rough-in10/25/201210/25/201210/25/2012APASS
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Kelly Perryman. ok to insulate.
BLD-Framing/Rough-in10/23/201210/23/201210/23/2012PPART
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Kelly Perryman. Complete all firestopping, brovide blocking for interior shear walls. Still needs fire sprinkler and alarm rough in inspections. No cover at this time.
BLD-Framing/Rough-in10/19/201210/19/201210/19/2012PPART
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Kelly Perryman. 1st. floor only, no cover at this time. Fire sprinkler rough in inspection failed. Also noted missing fire caulking for low voltage wiring (fire alarm) unprotected penetration through horizontal asssembly. Contractor to provide approverd UL rated assembly for membrane penetration of bulk wiring through 1hr corridor.
BLD-Wall Bracing10/5/201210/5/201210/5/2012PPASS
DetailsTom Arcoraci
Phone #: ###-#### >> Inspection requested via web by Kelly Perryman