Permit Number | BLD12-01123 |
Status | Issued |
Name |
PIONEER WATERPROOFING COMPANY INC
|
Site Address |
1001 W IDAHO ST
|
Project Name | WASHINGTON FEDERAL |
Customer Number | |
ePlanReview | No |
Description |
(WASHINGTON FEDERAL - GARAGE REPAIR) 6/25/12 Plan Modification - Expand scope of work to include removal of existing topping slab and replace with new reinforced topping slab over existing precast beams. drs To make repairs to existing concrete columns, "T"- Beams, and support ledges in accordance with the engineered details and referenced standards of the reviewed plans. Change out steel support structure for security gate. Special Inspection is required as indicated in the Statement of Special Inspections, to include the epoxy injection procedure, form and pour/pump procedure, reinforcing bar replacement and Sheet S0.01, Tests & Inspections; and as required by the Evaluation Services Report (ESR) for special products proposed for use in this project. The scope and intent of work is to "restore the structural elements of the garage to their design sections and strength" and damage being repaired is classified as "not substantial" based on substantial definition in 3405, IBC, per engineer. drs
|