Permit Information
Permit NumberBLD12-01281
StatusFinaled
Name ESI
Site Address 877 W MAIN ST Unit: 1000
Project NameWELLS FARGO 9th & 10th FLR
Customer Number 
ePlanReviewNo
Description
(HAWLEY TROXELL LAW FIRM - 9TH & 10TH FLOORS - SUITE 1000) (9-4-12 PLAN MODIFICATION TO CREATE TWO NEW CONFERENCE ROOMS ON THE 10TH STORY IN THE SAME LOCATION WHERE ONE CONFERENCE ROOM WAS PROPOSED BEFORE.) This building is required to have a fire sprinkler system because it is a high-rise building. To remodel portions of an existing tenant space located on the 9th story and 10th story of the Wells Fargo Building. This tenant space has a total floor area of about 30,266 square feet (15,133 square feet per story). Work is to include interior nonbearing walls, interior doors, millwork, and finishes. The restrooms located on each story will be upgraded to be more accessible to the disabled. The existing door hardware throughout this tenant space will be replaced with lever hardware. In conjunction with this permit, the fire sprinkler heads throughout both stories will be replaced with quick-response heads. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection12/10/201212/11/201212/11/2012PPASS
DetailsForrest France
Fire life safety inspection completed satisfactory.
BLD-Final12/10/201212/11/201212/11/2012PPASS
DetailsDave Hannah
Please call an hour prior to arrival if at all possible. Thanks, Chris Phone #: ###-#### >> Inspection requested via web by Chris Palmer
FIRE-Sprinkler Rough-in11/20/201211/20/201211/20/2012APASS
DetailsForrest France
Project related fire sprinkler permit finaled.
BLD-Framing/Rough-in10/18/201210/18/201210/18/2012PPASS
DetailsDave Hannah
Inspecting rooms 910, 911A, 911B, 912. Rooms are located on the 9th floor next to the main elevator lobby. Plans are located at the reception desk on the 10th floor. Please call with any questions. Thanks, Chris Phone #: ###-#### >> Inspection requested via web by Chris Palmer
BLD-Framing/Rough-in9/14/20129/14/20129/17/2012PPASS
DetailsDave Hannah
Plans and permit at the reception desk on the 10th floor. Inspecting wall framing in rooms 1051, 1052, 957, 958. Please call Chris approx 1 hr prior to arrival if at all possible. Thank You. Phone #: ###-#### >> Inspection requested via web by Chris Palmer