BLD-Final | 11/20/2012 | 11/21/2012 | 11/21/2012 | P | PASS |
Mike Jordan
|
|
|
Cameron Phone #: ###-####
|
DOC - Permit Finaled | 11/21/2012 | 11/21/2012 | 11/21/2012 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 11/19/2012 | 11/20/2012 | 11/20/2012 | P | FAIL |
Mike Jordan
|
|
|
Cameron-please call for access code Phone #: ###-####. Provide the blower door test result and energy cert.
|
BLD-Wall Bracing | 10/2/2012 | 10/3/2012 | 10/3/2012 | A | PASS |
Tom Arcoraci
|
|
|
Cameron Phone #: ###-####
|
BLD-Framing/Rough-in | 9/27/2012 | 9/28/2012 | 9/28/2012 | P | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
BLD-Energy code compliance | 9/28/2012 | 9/28/2012 | 9/28/2012 | P | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
BLD-Framing/Rough-in | 9/26/2012 | 9/27/2012 | 9/27/2012 | A | FAIL |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Complete lateral bracing, see engineering, provide bracing on top chords of C2A trusses at overbuild. Provide alll required blocking for interior wall bracing per IRC 602.10.6. Correction notice posted. Ok to insulate.
|
BLD-Wall Bracing | 9/18/2012 | 9/19/2012 | 9/19/2012 | A | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Wall bracing ok to cover.
|
BLD-Wall Bracing | 9/17/2012 | 9/18/2012 | 9/18/2012 | A | FAIL |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Block panel splices @portal frame and nail at 3" oc with 8d nails. See portal frame detail and complete nailing pattern at upper section. Renail all areas, nailing is over spaced adn several areas missed. Correction notice posted.
|
BLD-Wall Bracing | 9/13/2012 | 9/17/2012 | 9/17/2012 | A | FAIL |
Mike Jordan
|
|
|
Shear - Cameron Phone #: ###-####. Provide city set of approved plans. Correction notice posted.
|
BLD-Wall Bracing | 9/13/2012 | 9/14/2012 | 9/14/2012 | A | PASS |
Mike Jordan
|
|
|
Cameron Phone #: ###-####
|
BLD-Footing | 8/21/2012 | 8/22/2012 | 8/22/2012 | A | PASS |
Mike Jordan
|
|
|
BILL Phone #: ###-####
|
BLD-Footing | 8/20/2012 | 8/21/2012 | 8/21/2012 | P | NR |
Mike Jordan
|
|
|
bill Phone #: ###-####. No one on site, no forms constructed.
|