Permit Information
Permit NumberBLD12-03321
StatusFinaled
Name HILL CONSTRUCTION CO
Site Address 2588 N BOGUS BASIN RD
Project NameThe Pursuit Church
Customer Number 
ePlanReviewYes
Description
(THE PURSUIT CHURCH) Fire sprinkler system used for building area increase. To convert a 15,885 square foot existing tenant space to a church. This tenant space was formerly use as a grocery store. Work is to include 2 multi-user toilet rooms accessible to the disabled, 2 single user shower / toilet rooms accessible to the disabled, a single user kid’s toilet room accessible to the disabled, a multi-user kid’s toilet room accessible to the disabled, interior nonbearing walls, suspended acoustical ceilings, gypsum board ceilings, exterior doors, interior doors, interior windows, platforms, a wheelchair lift to serve the Worship Auditorium platform, ramps to serve other platforms, interior stairways, millwork, and finishes. A new doorway will be created in an exterior masonry wall. A steel header and 2 steel jambs will be provided. This tenant space is required to be separated from the rest of the building by a 1-hr fire-resistance-rated fire barrier wall to create separate fire areas for fire alarm coverage. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 (including concealed combustible spaces) and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. A separate building permit will be required to finish the kitchen. Depending on the cooking operations, sewer grease abatement and/or grease hoods may be required. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/19/20136/19/20136/19/2013PPASS
DetailsTony Young
clint Phone #: ###-####
BLD-Final6/13/20136/14/20136/14/2013AFAIL
DetailsJim Storey
clint Phone #: ###-#### 1 1/2 at handrail west side of stage so door makes clearance/ block ramp in back on south side exit ramp to the north.
BLD-Final6/12/20136/13/20136/13/2013ANR
DetailsJim Storey
clint Phone #: ###-#### need mec sign off/ no insp.
FIRE-Final Inspection6/3/20136/4/20136/4/2013PPASS
DetailsForrest France
Fire life safety inspection completed satisfactory. Noted correction items finished.
FIRE-Conference5/28/20135/28/20135/28/2013ADONE
DetailsForrest France
Items noted during walkthrough include; building address location, missing exit discharge lighting, missing two exit signs from the kids chruch, missing EM lighting at room 123, door hardware at four breakout rooms and four meeting rooms is non-compliant, repair three EM lights, missing two exit signs at the lobby/lg. meeting room, overspaced fire extinguishers, mechanical mezzanine not shown on plans, missing small documents including the fire code review notes. Need to remove planter at the main entry/exit, post max. occupant load signage per plan annotations.
BLD-Final5/24/20135/24/20135/24/2013PNR
DetailsMike Jordan
Clint Phone #: ###-####. Needs fire/life/safety finals.
FIRE-Conference5/23/20135/23/20135/23/2013ADONE
DetailsForrest France
Discussion with contractor regarding fire life safety conditions for final approval, project schedule and related FIR trade work corrections.
FIRE-Conference5/14/20135/14/20135/14/2013PDONE
DetailsForrest France
Regarding project related FIR trade permit work.
BLD-Energy code compliance5/13/20135/13/20135/13/2013PDONE
DetailsTony Young
Clint Phone #: ###-####
BLD-Energy code compliance4/17/20134/18/20134/18/2013APART
DetailsTony Young
Clint Phone #: ###-####,, bathroom walls ok,, conf on stage frame/insulation/sprinklers,, pending clarification
BLD-Energy code compliance4/8/20134/9/20134/10/2013PPART
DetailsTony Young
clint Phone #: ###-####,, ok to cover interior walls (steel studs)
BLD-Wall cover3/21/20133/22/20133/22/2013APART
DetailsTony Young
Clint Phone #: ###-####,, some interior walls on north side ok for cover,, pending trades
BLD-Framing/Rough-in3/14/20133/15/20133/15/2013APART
DetailsTony Young
Clint Phone #: ###-####,, north interior walls ok to insulate,, pending elec. rough pass,,, talked to architect,, he will get as built or change ok for wall types