Permit Information
Permit NumberBLD13-00308
StatusFinaled
Name WESTERN IDAHO BUILDERS
Site Address 9016 W USTICK RD
Project NameJacksons Store 119
Customer Number 
ePlanReviewYes
Description
(JACKSON'S STORE 119 - REMODEL AND ADDITION) This building does not have a fire sprinkler system. To remodel an existing convenience store and to construct a 400 square foot addition. After the addition and including the 320 square foot canopy, this building will have a total floor area of about 3,000 square feet. Work is to include a restroom accessible to the disabled, walk-in coolers, a walk-in freezer, millwork, suspended acoustical ceilings, gypsum board ceilings and soffits, R-20 continuous insulation installed on top of the existing roof deck, a new membrane roof covering, new storefront windows and door, and interior finishes. The addition includes masonry exterior walls, wood ledgers, wood roof joists, wood roof sheathing, continuous exterior wall insulation, R-20 insulation installed on top of the roof deck, a membrane roof covering, and an exterior door. Exterior work includes 3-coat wall plaster, EPS decorative bands, cultured stone, new parapets installed at the end of the existing roof cantilever, new prefabricated metal awnings installed at the end of the existing roof cantilever, decorative parapets, and a new trash enclosure. The design and attachment of the new prefabricated metal awnings are deferred submittal items. Upgrade work includes attaching the existing roof diaphragm to the existing exterior walls with epoxy anchors and steel straps and constructing a 30 inch high fire-resistance-rated parapet on the West wall. Special inspection is required for soils, concrete, masonry, welding, and epoxy anchors. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference8/13/20138/13/20138/13/2013PDONE
DetailsJim Sly
Called Jackson Food Stores....Left Robert a V/M.......Need to obtain Perm Occ. Need P/W and Zoning final.
BLD-Aging Inspection8/9/20138/9/20138/13/2013 DONE
DetailsJim Sly
BLD-Final5/22/20135/23/20135/23/2013PPART
DetailsJim Sly
Kenny-Early pm please Phone #: ###-####
OK for Temp Occ. OK for Perm Occ. when Public Works and Zoning Perms.
BLD-Final5/21/20135/22/20135/23/2013PCANC
DetailsJim Sly
Kenny Phone #: ###-####
FIRE-Final Inspection5/22/20135/23/20135/23/2013APASS
DetailsTroy Cobbley
Life safety passed
FIRE-Final Inspection5/22/20135/22/20135/22/2013PFAIL
DetailsTroy Cobbley
The contractor had the approved plans but still does not have the small documents. I explained the electronic plan review process and the need for all of the documents. Fire extinguisher has been provided at pumps.
FIRE-Final Inspection5/21/20135/22/20135/22/2013AFAIL
DetailsTroy Cobbley
No city approved plans or notes on site. I noted that a fire extinguisher is required at the pumps since they exceed 75' from the one in the building.
BLD-Ceiling Grid Inspection5/16/20135/17/20135/17/2013PPASS
DetailsJim Sly
kenny Phone #: ###-####
BLD-Footing5/6/20135/7/20135/7/2013PCANC
DetailsJim Sly
###-#### customer would like around 2:00 PM
BLD-Conference5/1/20135/2/20135/2/2013APASS
DetailsJim Sly
chuck Phone #: ###-####
Note..........Inspection and approval of front Canopy Framing...OK.
BLD-Other4/25/20134/29/20134/29/2013APASS
DetailsJim Sly
request 8:30/grout insp//Chuck Phone #: ###-####
OK Pending MTI insp, tests, and approvals.
BLD-Framing/Rough-in4/25/20134/26/20134/26/2013PPART
DetailsJim Sly
request 3:30///Chuck Phone #: ###-####
Interior walls....OK.
BLD-Other4/25/20134/26/20134/26/2013PPART
DetailsJim Sly
request 3:30//grout insp//Chuck Phone #: ###-####
Cmu wall...partial...OK pending MTI insp, tests and approvals.
BLD-Foundation4/18/20134/19/20134/19/2013PPASS
DetailsJim Sly
pouring at 1 - chuck Phone #: ###-####
BLD-Footing4/16/20134/17/20134/17/2013APASS
DetailsJim Sly
Around 9:00 if possible please-Chuck Phone #: ###-####
Epoxy dowels MTI.......Footing...No special insp. required per Engineer. CMU wall requires special inspection.