Permit Information
Permit NumberBLD13-00414
StatusFinaled
Name ST LUKES REG MED CNTR
Site Address 190 E BANNOCK ST
Project NameST LUKES - 10TH FLOOR
Customer Number 
ePlanReviewNo
Description
(ST LUKES - NEURO SURGERY CLINIC - 10TH STORY) Fire sprinkler system used for high-rise and for occupancy. To remodel the 7,909 square foot 10th story of the St. Luke’s hospital. The occupied area of the 10th story includes medical exam and treatment rooms, a waiting room, a terrace, a conference room, and offices. At the same level as the occupied area of the 10th story is a roof area open to the sky with roof top HVAC equipment installed. The existing 2 separate smoke compartments will be maintained with a 1-hr smoke barrier wall between them. The existing I-2 Occupancy type corridor will also be maintained. Work is to include a toilet room accessible to the disabled, a bariatric toilet room accessible to those who are overweight, interior nonbearing walls, 1-hr fire-resistance-rated smoke barrier walls, I-2 Occupancy corridor walls and doors, smoke partitions, suspended acoustical ceilings, a dual height drinking fountain, millwork, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Quick-response fire sprinkler heads are required throughout the occupied area of the 10th Story. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/20/20143/26/20143/26/2014APASS
DetailsDave Hannah
if no answer call ###-#### Phone #: ###-#### >> Inspection requested via web by Rock Self
FIRE-Final Inspection3/20/20143/24/20143/24/2014APASS
DetailsForrest France
Fire life safety completed satisfactory.
BLD-Wall cover1/30/20141/31/20141/31/2014APASS
DetailsDave Hannah
if no answer try ###-#### please Phone #: ###-#### >> Inspection requested via web by Rock Self
BLD-Ceiling Grid Inspection12/11/201312/11/201312/11/2013APEND
DetailsDave Hannah
if no answer try my desk phone ###-#### Phone #: ###-#### >> Inspection requested via web by Rock Self
BLD-Wall cover10/31/201311/1/201311/1/2013PPASS
DetailsDave Hannah
if no answer try my desk phone at ###-#### Thanks Phone #: ###-#### >> Inspection requested via web by Rock Self