Permit Information
Permit NumberBLD13-01289
StatusFinaled
Name TRILOGY DEVELOPMENT INC
Site Address 1377 S GOLDKING WAY
Project NameUnion Square Apts - Phase II
Customer Number 
ePlanReviewNo
Description
(UNION SQUARE APTS)(BLDG#15) To construct a wood frame, three story, 28,041 sq. ft., 24 Unit Multi Family Dwellings - 1 (1B/1B Type 'A'), 4 (2B/2B Type 'B'), 3 (1B/1B Type 'B'), 8 (2B/2B), and 8 (1B/1B), per reviewed plans. All units exceed 800 sq. ft., are fully sprinklered W/ alarm. Work includes associated site work, footing & foundation, structural & non-structural framing; electrical, mechanical, plumbing, sprinkler & alarm work; fire-resistive construction between units, at stair enclosures or rated corridor breezeways; accessible Type 'A' & 'B' units; interior cabinetry, wall, floor and ceiling finishes and fixtures. All work shall comply with the approved drawings, the plan review report, and all applicable codes. This building will be fire sprinkled with a 13R sprinkler system. **SRZ** DRH13-00005 CUP12-00064
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/27/20142/28/20142/28/2014APASS
DetailsTom Arcoraci
The hand rail height problem has been corrected Phone #: ###-#### >> Inspection requested via web by Mike McHargue
BLD-Final2/27/20142/27/20142/27/2014PCANC
DetailsMike Jordan
BLD-Final2/26/20142/27/20142/27/2014AFAIL
DetailsMike Jordan
bld15 final Phone #: ###-#### >> Inspection requested via web by Mike McHargue. Provide code compliant handrail. Everything else ok.
FIRE-Final Inspection2/26/20142/26/20142/26/2014PPASS
DetailsTroy Cobbley
Life Safety Passed
BLD-Wall cover11/25/201311/26/201311/26/2013APASS
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargue. 1st and 2nd. floor north and south units, firestopping, and shearwalls ok. central units, 2nd. floor only.
BLD-Wall cover11/15/201311/15/201311/15/2013APASS
DetailsMike Jordan
first floor Phone #: ###-#### >> Inspection requested via web by Mike McHargue. All remaining units ok to cover.
BLD-Wall cover11/13/201311/14/201311/14/2013APART
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargue. Work in progress on remaining units, 1st and 2nd layers on 1st floor central units and south units ok.
BLD-Wall cover11/11/201311/12/201311/12/2013APASS
DetailsMike Jordan
fire caulking / framing Phone #: ###-#### >> Inspection requested via web by Mike McHargue. 2nd. floor center units and south units ok to cover. ok for 2nd layer on ceiling at first floor center and south units.
BLD-Wall cover11/7/201311/8/201311/8/2013APASS
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargue. 1st and 2nd floor north end units ok for tape. 3rd floor central units ok for tape.
BLD-Wall cover11/7/201311/7/201311/7/2013APART
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargue. work in progress.
BLD-Wall cover11/6/201311/6/201311/6/2013PPART
DetailsMike Jordan
Drywall screws Phone #: ###-#### >> Inspection requested via web by Mike McHargue. Work in progress on on interior shearwalls and party walls. No new units ready.
BLD-Wall cover11/5/201311/5/201311/5/2013APASS
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargue. North units, 2nd. floor 1st. layer ok.
BLD-Wall cover11/4/201311/4/201311/4/2013PPART
DetailsMike Jordan
Screw inspection Phone #: ###-#### >> Inspection requested via web by Mike McHargue. 3rd floor, North and south end units, interior shear walls, party walls and corridor walls ok. All firestopping completed. Ok to tape and cover.
BLD-Energy code compliance10/29/201310/29/201310/29/2013PPASS
DetailsMike Jordan
Insulation Phone #: ###-#### >> Inspection requested via web by Mike McHargue
BLD-Energy code compliance10/28/201310/29/201310/29/2013ANR
DetailsMike Jordan
Insulation Phone #: ###-#### >> Inspection requested via web by Mike McHargue
BLD-Energy code compliance10/25/201310/28/201310/28/2013ANR
DetailsMike Jordan
Insulation Phone #: ###-#### >> Inspection requested via web by Mike McHargue
BLD-Energy code compliance10/24/201310/24/201310/24/2013PPASS
DetailsMike Jordan
Air Seal Phone #: ###-#### >> Inspection requested via web by Mike McHargue. Airseal has been completed.
BLD-Framing/Rough-in10/24/201310/24/201310/24/2013PPART
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargueok to insulate 1st. 2nd. and 3rd. floors. All firestopping completred. fireblock at 3rdfloor ceiling behind tubs. Provide additional 5/8 type x sheet rock at chases, 2nd. floor vent fans. Add straps at double top plate splices in same spot.
FIRE-Sprinkler Rough-in10/23/201310/23/201310/23/2013PPASS
DetailsTroy Cobbley
Tenting in attic space is approved. Piping can be covered.
BLD-Conference10/22/201310/22/201310/22/2013PDONE
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargue
BLD-Wall cover10/18/201310/21/201310/21/2013PCANC
DetailsMike Jordan
Fire Caulking Phone #: ###-#### >> Inspection requested via web by Mike McHargue. Inspection done in the am.
BLD-Framing/Rough-in10/18/201310/21/201310/21/2013APART
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Mike McHargue. Walk through on 1st. floor only. Work in progress on firestopping. All trades not yet inspected. No cover at this time.
BLD-Wall Bracing9/10/20139/10/20139/10/2013APASS
DetailsMike Jordan
Sheer Phone #: ###-#### >> Inspection requested via web by Mike McHargue. 1st, 2nd and 3rd floor exterior shearwalls ok. ok to cover exterior of building.
BLD-Wall Bracing9/9/20139/9/20139/9/2013PFAIL
DetailsMike Jordan
Exterior Sheer Phone #: ###-#### >> Inspection requested via web by Mike McHargu. All floor to floor straps on exterior sheathing installed. Noted several areas were nailing was missing or needs to be tightened up.
BLD-Wall Bracing8/26/20138/26/20138/26/2013AFAIL
DetailsMike Jordan
First two floors of building 15 sheer / straps / hold downs. Phone #: ###-#### >> Inspection requested via web by Mike McHargue. Several areas missing nailing and holdowns need to be tightened down.