Permit Information
Permit NumberBLD13-02102
StatusFinaled
Name CUSTOM STEEL STRUCTURES
Site Address 7908 W WOODLARK ST
Project NameBolen's Control House
Customer Number 
ePlanReviewNo
Description
(Bolen's Control House - Addition) MODIFICATION TO REMOVE TWO NONBEARING WALLS FROM THE EXISTING OFFICE AREA. Permit for the addition of 1,290 sq ft of office space to an existing to an existing 7,265 sq. ft. building with work to include wood framed exterior walls with steel siding and a manufatured wood truss roof with standing seam metal roofing. There will be a new opening cut in the existing building to connect the two areas. The office area in the existing area will be reduced from 1,642 sq. ft. to 838 sq. ft. with approximately 30 lineal feet of interior nonbearing wall being constructed. All work per the approved plans, any notations and the attached engineering. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/24/20149/24/20149/24/2014PPASS
DetailsMike Jordan
Curt Phone #: ###-####. Ok for prm. occ.
FIRE-Final Inspection8/14/20148/14/20148/14/2014PPASS
DetailsForrest France
Verified plan resubmittals and previous correction items. Life safety final approved.
BLD-Final8/14/20148/14/20148/14/2014PPART
DetailsMike Jordan
call before// Curt Phone #: ###-####. Ok for temp occ. Needs to install high/low drinking fountain.
FIRE-Final Inspection7/8/20147/9/20147/9/2014AFAIL
DetailsTroy Cobbley
Resubmit plans showing the correct door/exit path layout with the desited exit sign arrangement for approval. Also show the new wall being deleted. Install fire extinguisher as discussed.
BLD-Conference5/12/20145/13/20145/13/2014ADONE
DetailsMike Jordan
Kurt-pleae call for access Phone #: ###-####
BLD-Energy code compliance2/24/20142/24/20142/24/2014PPASS
DetailsMike Jordan
Curtis Phone #: ###-####
BLD-Framing/Rough-in2/14/20142/18/20142/18/2014PPASS
DetailsMike Jordan
Curt Phone #: ###-####. All framing issues resolved. Ok to insulate.
BLD-Framing/Rough-in2/11/20142/11/20142/11/2014PFAIL
DetailsMike Jordan
curtis Phone #: ###-####. Airseal pack to be completed prior to framing inspection. Provide additional nailing on 3 ply T03 truss as well as the required 14 SDS screws on 2x6 blocks at both bearing ends. Correction notice posted.
BLD-Wall Bracing1/8/20141/9/20141/9/2014APASS
DetailsMike Jordan
Curt Phone #: ###-####. North wall ok to cover.
BLD-Other1/6/20141/6/20141/6/2014PPART
DetailsMike Jordan
curt - shear inspection Phone #: ###-####. Needs to complete the north side of building, connect holddowns, and complete sheathing.
BLD-Foundation10/25/201310/28/201310/28/2013APASS
DetailsMike Jordan
JOHN Phone #: ###-####
BLD-Foundation10/24/201310/25/201310/25/2013PCANC
DetailsMike Jordan
John Phone #: ###-####
BLD-Footing10/25/201310/25/201310/25/2013PPASS
DetailsMike Jordan
John Phone #: ###-####. All issues have been resolved.
BLD-Footing10/25/201310/25/201310/25/2013APASS
DetailsMike Jordan
John Phone #: ###-####. All issues have been resolved. 2500 psi for design, clearance issues resolved. also noted per engineers letter that as built condtion at existing building is acceptable.
BLD-Footing10/21/201310/22/201310/22/2013AFAIL
DetailsMike Jordan
John MIller Phone #: ###-####. Provide additional chairs on north footing line to provide the min. required clearances. Provide RFI from engineer for change in field conditions for connection to existing footing. Provide specified conc psi to be used and concrete design psi by engineer. Correction notice posted. Also noted ESC issues. No concrete allowed at this time.