Permit Number | BLD13-02128 |
Status | Finaled |
Name |
HC COMPANY INC
|
Site Address |
1114 W FRONT ST
|
Project Name | WOODLAND EMPIRE ALE CRAFT |
Customer Number | |
ePlanReview | No |
Description |
(WOODLAND EMPIRE ALE CRAFT) This building does not have a fire sprinkler system. To remodel an existing 8,641 square foot building for a brewery with tasting room. The occupant load of the entire building will exceed 100. To avoid installing a fire sprinkler system, two fire areas will be created. The A-2 fire area will have a floor area of about 1,465 square feet and an occupant load of 71. The F-1, S-1, and B fire area will have a floor area of about 7,176 square feet and an occupant load of 52. Work is to include 3-hr fire barrier walls, 3-hr fire doors, a 1-hr incidental use separation with a 60 minute fire door, 2 restrooms accessible to the disabled, interior nonbearing walls, interior doors, new exterior windows, new exterior doors, an alcove at an exterior door, a new awning, a parking space accessible to the disabled, and new exterior landings at doors. Special Inspection is required for welding and masonry anchors. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
|