BLD-Final | 1/13/2015 | 1/14/2015 | 1/13/2015 | A | PASS |
Phil Shearer
|
|
|
Richard Phone #: ###-####
|
FIRE-Final Inspection | 1/13/2015 | 1/14/2015 | 1/13/2015 | A | PASS |
Troy Cobbley
|
|
|
life safety passed
|
BLD-Final | 1/12/2015 | 1/12/2015 | 1/12/2015 | P | CANC |
Phil Shearer
|
|
|
Please return after all signatures are logged into system to review for final inspection and C of O Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
FIRE-Final Inspection | 1/12/2015 | 1/12/2015 | 1/12/2015 | P | FAIL |
Troy Cobbley
|
|
|
Need to provide fire dept approval on tanks, scott has approved existing fire dept access without utilizing the east side driveway, and the two emergency stop buttons along Orchard Street do not work.
|
BLD-Final | 1/7/2015 | 1/9/2015 | 1/9/2015 | P | CANC |
Phil Shearer
|
|
|
Please come after 3 pm for final inspection. Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
FIRE-Final Inspection | 1/7/2015 | 1/9/2015 | 1/9/2015 | A | FAIL |
Troy Cobbley
|
|
|
See posted correction notice that includes: Provide fire dept sign off, remove thumbturn on main exit and provide sticker, remove deadbolt from beer cooler door, provide all small documents including fire dept review comments, repair and finish installing exit discharge lighting, test duct smoke detectors, provide signage for emergency stop and at gas pumps, test emergency stop...ect.
|
BLD-Final | 1/8/2015 | 1/9/2015 | 1/9/2015 | A | CANC |
Phil Shearer
|
|
|
Richard Phone #: ###-####
|
BLD-Final | 1/7/2015 | 1/7/2015 | 1/7/2015 | P | CANC |
Phil Shearer
|
|
|
Please come around 3pm for the final walkthru Phone #: ###-#### >> Inspection requested via web by Richard Fontaine Inspection cancelled from web by: Richard Fontaine
|
FIRE-Conference | 12/12/2014 | 12/12/2014 | 12/12/2014 | P | DONE |
Troy Cobbley
|
|
|
Discussed address placement
|
BLD-Wall cover | 11/24/2014 | 11/24/2014 | 11/24/2014 | P | PASS |
Phil Shearer
|
|
|
Please inspect wall cover later in the afternoon. Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
BLD-Energy code compliance | 11/20/2014 | 11/21/2014 | 11/21/2014 | A | PASS |
Phil Shearer
|
|
|
Please come early AM to inspect interior insulation prior to Sheetrock Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
BLD-Framing/Rough-in | 11/21/2014 | 11/21/2014 | 11/21/2014 | P | PASS |
Phil Shearer
|
|
|
Please come early AM to inspect interior insulation prior to Sheetrock Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
BLD-Framing/Rough-in | 11/18/2014 | 11/19/2014 | 11/19/2014 | P | PART |
Phil Shearer
|
|
|
Please inspect towards the end of the day on Wednesday for approval to insulate. Phone #: ###-#### Inspection requested via web by Richard Fontaine. ok except for front high wall has not passed electrical inspection
|
BLD-Framing/Rough-in | 11/12/2014 | 11/13/2014 | 11/13/2014 | P | PART |
Phil Shearer
|
|
|
Partial wall inspection prior to partial insulation behind beer cooler Phone #: ###-#### Inspection requested via web by Richard Fontaine.
|
BLD-Wall Bracing | 10/31/2014 | 11/3/2014 | 11/3/2014 | P | PASS |
Phil Shearer
|
|
|
Shear wall inspection sometime during the afternoon please. Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
BLD-Energy code compliance | 9/30/2014 | 9/30/2014 | 9/30/2014 | P | PASS |
Phil Shearer
|
|
|
Please inspect the foundation insulation around 3 pm Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
BLD-Foundation | 9/25/2014 | 9/29/2014 | 9/29/2014 | A | PASS |
Phil Shearer
|
|
|
We are pouring the foundation stem walls at 10 am. Please inspect prior Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
BLD-Footing | 9/22/2014 | 9/24/2014 | 9/24/2014 | A | PASS |
Phil Shearer
|
|
|
We are pouring building footings at 10 a.m. Please inspect prior to this. Phone #: ###-#### Inspection requested via web by Richard Fontaine
|
BLD-Footing | 9/17/2014 | 9/18/2014 | 9/18/2014 | A | PASS |
Phil Shearer
|
|
|
Canopy column footings and overview of work to be performed. (Conference) Phone #: ###-#### Inspection requested via web by Richard Fontaine
|