Permit Information
Permit NumberBLD14-00203
StatusFinaled
Name ANDERSEN CONSTRUCTION CO
Site Address 10816 W FLORENCE DR
Project NameCordillera Development
Customer Number 
ePlanReviewNo
Description
(CORDILLERA DEVELOPMENT - BLDG 1) To construct a new 3,668 sq. ft., two story, Four unit, apartment building. Units 'A' have one bedroom, one den, and two bathrooms. Units 'B' have two bedrooms, and two bathrooms. All 4 dwelling units have their own independent exit. All construction per the approved plans, attached plan review report, and all other reviewing agencies approvals. One hour fire-partition separations are required between dwelling units. This building is required to be fire sprinklered. The fire sprinkler system shall be per NFPA 13R as regulated by the fire department. DRH13-00288 Per Planning and Zoning. **SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection7/8/20157/8/20157/9/2015 PASS
DetailsMike Jordan
DOC - Permit Finaled7/9/20157/9/20157/9/2015PPASS
DetailsMike Jordan
BLD-Final4/9/20154/9/20154/9/2015PPASS
DetailsMike Jordan
Dave Phone #: ###-####
BLD-Aging Inspection3/30/20153/30/20153/30/2015 PASS
DetailsMike Jordan
BLD-Aging Inspection1/26/20151/26/20151/27/2015 PASS
DetailsMike Jordan
BLD-Final11/6/201411/6/201411/6/2014PPART
DetailsMike Jordan
Tyler Phone #: ###-####. 1hr. const. complete in riser room. ok for temp occ.
BLD-Final11/5/201411/6/201411/6/2014AFAIL
DetailsMike Jordan
Tyler Phone #: ###-####. Provide the required 1hr. construction in the fire riser rm.
FIRE-Final Inspection11/4/201411/5/201411/5/2014APASS
DetailsTroy Cobbley
Life safety passed. Building address to be mounted prior to the final inspection
BLD-Energy code compliance9/9/20149/10/20149/10/2014PPASS
DetailsMike Jordan
Richard Phone #: ###-####
BLD-Framing/Rough-in9/9/20149/9/20149/9/2014PPASS
DetailsMike Jordan
Richard Phone #: ###-####
BLD-Wall Bracing8/15/20148/15/20148/15/2014PPASS
DetailsMike Jordan
Richard Phone #: ###-####. floor to floor straps ok.
BLD-Wall Bracing8/14/20148/14/20148/14/2014PNR
DetailsMike Jordan
Richard Phone #: ###-####
BLD-Wall Bracing8/11/20148/12/20148/12/2014APASS
DetailsMike Jordan
Richard Phone #: ###-####. Roof strapping ok.
BLD-Wall Bracing7/31/20147/31/20147/31/2014PPASS
DetailsPhil Shearer
Richard Phone #: ###-####
All exterior shear walls ok
BLD-Wall Bracing7/30/20147/30/20147/30/2014PPASS
DetailsPhil Shearer
Richard Phone #: ###-####
2nd floor exterior shear walls ok
BLD-Wall Bracing7/21/20147/21/20147/21/2014PNR
DetailsMike Jordan
Ken Phone #: ###-####
BLD-Wall Bracing7/18/20147/18/20147/18/2014PPASS
DetailsMike Jordan
Ken Phone #: ###-####. 1st floor exterior shear walls and interior shear walls only ok.
BLD-Energy code compliance6/27/20147/1/20147/1/2014APASS
DetailsMike Jordan
Ashley Phone #: ###-####. rigid insulation, interior side of stemwaal under slab on grade.
BLD-Foundation6/25/20146/26/20146/26/2014PPASS
DetailsMike Jordan
Manual Phone #: ###-####
BLD-Footing6/25/20146/25/20146/25/2014PPASS
DetailsMike Jordan