Permit Information
Permit NumberBLD14-00216
StatusFinaled
Name ANDERSEN CONSTRUCTION CO
Site Address 10830 W FLORENCE DR
Project NameCordillera Development
Customer Number 
ePlanReviewNo
Description
(CORDILLERA DEVELOPMENT - BLDG 14) To construct a new 3,668 sq. ft., two story, Four unit, apartment building. Units 'A' have one bedroom, one den, and two bathrooms. Units 'B' have two bedrooms, and two bathrooms. All 4 dwelling units have their own independent exit. All construction per the approved plans, attached plan review report, and all other reviewing agencies approvals. One hour fire-partition separations are required between dwelling units. This building is required to be fire sprinklered. The fire sprinkler system shall be per NFPA 13R as regulated by the fire department. DRH13-00288 Per Planning and Zoning. See BLD14-00203 for Building Plan Review Report. **SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/9/20154/9/20154/9/2015PPASS
DetailsMike Jordan
Dave Phone #: ###-####
BLD-Aging Inspection4/6/20154/6/20154/6/2015 PASS
DetailsMike Jordan
BLD-Final12/16/201412/16/201412/16/2014PPART
DetailsMike Jordan
Tyler Phone #: ###-####. Ok for temp occ. Will be ok for perm occ. once zoning and public works signs perm.
BLD-Final12/15/201412/15/201412/15/2014PNR
DetailsMike Jordan
BLD-Final12/1/201412/2/201412/2/2014PNR
DetailsMike Jordan
tyler Phone #: ###-####
FIRE-Final Inspection12/1/201412/2/201412/2/2014APASS
DetailsTroy Cobbley
life safety passed
BLD-Final11/21/201411/24/201411/24/2014ANR
DetailsMike Jordan
Tyler Phone #: ###-####. Needs fire/life/safety finals.
FIRE-Final Inspection11/21/201411/21/201411/21/2014PCANC
DetailsTroy Cobbley
Left voice messag on Tyler's phone that fire alarm and fire sprinkler permits have not been inspected/finaled yet and are needed prior to a fire life safety final.
BLD-Framing/Rough-in10/2/201410/2/201410/2/2014PPASS
DetailsJim Sly
Richard Phone #: ###-####
BLD-Energy code compliance10/1/201410/2/201410/2/2014PPASS
DetailsJim Sly
Richard Phone #: ###-####
BLD-Framing/Rough-in10/1/201410/1/201410/1/2014PFAIL
DetailsMike Jordan
Richard Phone #: ###-####. Complete all draft stops in attic areas, repair the drholes in draft stop attic areas, complete all lateral bracing,Provide H2.5 on trusses at interior bearing walls at 2nd floor. Fireblock all furdowns, remove foam insulation from partwall penetrations and fire caulk. A tenting inspection for fire sprinklers is also required prior to energy code inspection. ok to insulate. Correction notice posted.
BLD-Wall Bracing9/2/20149/2/20149/2/2014PPASS
DetailsMike Jordan
Richard Phone #: ###-####. floor to floor straps.
BLD-Wall Bracing8/25/20148/26/20148/26/2014APASS
DetailsMike Jordan
Richard Phone #: ###-####. 2nd. floor interior shear walls ok.
BLD-Wall Bracing8/25/20148/25/20148/25/2014PPASS
DetailsMike Jordan
Richard Phone #: ###-####. remainder of 2nd. floor exterior shear walls ok.
BLD-Wall Bracing8/22/20148/25/20148/25/2014APASS
DetailsMike Jordan
Richard Phone #: ###-####. 2nd. floor exterior shear walls ok.
BLD-Wall Bracing8/21/20148/21/20148/21/2014PPASS
DetailsPhil Shearer
Richard Phone #: ###-#### 1st floor exterior shear walls OK. 2nd floor straping west side only OK
BLD-Wall Bracing8/20/20148/20/20148/20/2014PPASS
DetailsPhil Shearer
Richard Phone #: ###-#### Interior shear walls OK
BLD-Wall Bracing8/18/20148/19/20148/19/2014PPASS
DetailsMike Jordan
richard Phone #: ###-####
BLD-Footing7/30/20147/30/20147/30/2014PPASS
DetailsPhil Shearer
Interior footings
BLD-Footing7/29/20147/30/20147/30/2014ACANC
DetailsJim Sly
Ken--around 11 please Phone #: ###-####
Canc By Contr.
BLD-Energy code compliance7/25/20147/25/20147/25/2014PPASS
DetailsMike Jordan
Ashley Phone #: ###-####. rigid foam at stemwall under slab on grade.
BLD-Footing7/22/20147/23/20147/23/2014APASS
DetailsMike Jordan
Manuel Phone #: ###-####