BLD-Final | 8/13/2014 | 8/14/2014 | 8/14/2014 | P | PASS |
Jim Storey
|
|
|
eric Phone #: ###-####
|
FIRE-Final Inspection | 8/13/2014 | 8/14/2014 | 8/14/2014 | A | PASS |
Forrest France
|
|
|
Life safety inspection passed.
|
BLD-Ceiling Grid Inspection | 7/31/2014 | 7/31/2014 | 7/31/2014 | P | PASS |
Jim Sly
|
|
|
Eric Phone #: ###-####
|
BLD-Ceiling Grid Inspection | 7/15/2014 | 7/16/2014 | 7/16/2014 | A | NR |
Mike Jordan
|
|
|
Aaron Phone #: ###-####. Needs trades first.
|
BLD-Framing/Rough-in | 7/7/2014 | 7/7/2014 | 7/7/2014 | P | PASS |
Mike Jordan
|
|
|
Aaron-please go as close to 10 as possible Phone #: ###-####
|
BLD-Energy code compliance | 7/7/2014 | 7/7/2014 | 7/7/2014 | P | PASS |
Mike Jordan
|
|
|
Aaron-please go as close to 10 as possible Phone #: ###-####
|
BLD-Framing/Rough-in | 7/2/2014 | 7/3/2014 | 7/3/2014 | P | FAIL |
Mike Jordan
|
|
|
Eric Phone #: ###-####. Install additionalsquash blocking under 2ply girder truss. Install missing blocking on south shear wall. Justify missing bearing points at North A1 gable end truss. Review truss engineering for additional purlins not installed. Provide addition (2) 2x6 studs entire length of south A1 gable truss,attach to blocking and truss chords w/ 16D nails as per detail 7 A2.1. Provide web stiffmers with simpson DTC to interior wall per detail 8 A2.1. Correction notice posted.
|
BLD-Foundation | 5/6/2014 | 5/6/2014 | 5/6/2014 | P | PASS |
Tom Arcoraci
|
|
|
Rob Phone #: ###-####
|
BLD-Footing | 5/2/2014 | 5/2/2014 | 5/2/2014 | P | PASS |
Mike Jordan
|
|
|
eric Phone #: ###-####
|