BLD-Final | 12/15/2014 | 12/16/2014 | 12/16/2014 | A | PASS |
Tony Young
|
|
|
Key code front door: 3412 Paper work on kitchen island. Phone #: ###-#### Inspection requested via web by James Greenwood
|
DOC - Permit Finaled | 12/16/2014 | 12/16/2014 | 12/16/2014 | P | PASS |
Tony Young
|
|
|
c of o issued
|
BLD-Final | 12/15/2014 | 12/15/2014 | 12/15/2014 | P | PEND |
Tony Young
|
|
|
Key code front door: 3412 Paper work on kitchen island. Phone #: ###-#### Inspection requested via web by James Greenwood,, pending zoning
|
BLD-Final | 12/12/2014 | 12/15/2014 | 12/15/2014 | A | PEND |
Tony Young
|
|
|
Key code front door: 3412 Paper work on kitchen island. Phone #: ###-#### Inspection requested via web by James Greenwood,, ok pending zoning
|
BLD-Wall cover | 8/5/2014 | 8/5/2014 | 8/5/2014 | P | PASS |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by James Greenwood
|
BLD-Energy code compliance | 8/5/2014 | 8/5/2014 | 8/5/2014 | P | PASS |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by James Greenwood
|
BLD-Framing/Rough-in | 8/3/2014 | 8/4/2014 | 8/4/2014 | A | PASS |
Tony Young
|
|
|
Note: the nailing on one side of the girder trusses is hidden. The trusses are nailed according to plan. In order to see the nailing pattern, I’ve taken magnets and placed them along the truss to show where the nails are located due to the nail heads being covered by the adjoining truss. This can be viewed in the master bedroom along the bottom cord of the truss for a two foot span. Phone #: ###-#### Inspection requested via web by James Greenwood///, pass with the condition that...NOTE.., contractor is taking full responsibility of girder nailing.. ok to insulate
|
BLD-Framing/Rough-in | 7/30/2014 | 7/30/2014 | 7/30/2014 | A | PART |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by James Greenwood,, c/n listed on truss eng,, ok to insulate
|
BLD-Conference | 7/15/2014 | 7/16/2014 | 7/16/2014 | P | PASS |
Tony Young
|
|
|
Notify contractors that working hours begin at 7 am. Complaints received that they are starting at 6 am.,, talked with builder,, said workers have been talked to
|
BLD-Foundation | 5/28/2014 | 5/28/2014 | 5/28/2014 | P | PASS |
Tony Young
|
|
|
jerry Phone #: ###-####
|
BLD-Footing | 5/27/2014 | 5/28/2014 | 5/28/2014 | A | PASS |
Jim Sly
|
|
|
Jimmy Phone #: ###-####
|
BLD-Foundation | 5/5/2014 | 5/5/2014 | 5/5/2014 | P | PART |
Tony Young
|
|
|
Dane Phone #: ###-####,, basement wall ok
|
BLD-Footing | 5/1/2014 | 5/1/2014 | 5/1/2014 | P | PASS |
Jim Sly
|
|
|
dane Phone #: ###-####
|
BLD-Other | 4/28/2014 | 4/28/2014 | 4/28/2014 | P | DONE |
Tony Young
|
|
|
Pre-construction Erosion and Sediment control. Phone #: ###-#### >> Inspection requested via web by James Greenwood,, done by Andy L. under the ESC permit
|