Permit Number | BLD14-01601 |
Status | Finaled |
Name |
TALBOY CONSTRUCTION
|
Site Address |
7293 W AIRWAY CT
|
Project Name | Cooler Installation |
Customer Number | |
ePlanReview | No |
Description |
(NORTHWEST SPECIALTY BEVERAGE COMPANY – Beverage Cooler) C of O under BLD14-00330. This permit is for the construction of a 640 sq ft site built cooler inside a distribution warehouse. This cooler must be installed in accordance with the approved plans and redlines made within. This cooler shall meet the requirements for finish material from chapter 26 of the 2012 IBC. All foam must be protected by ½ inch gypsum or 0.032 aluminum / corrosion resistant steel. This building is fully sprinklered. Please contact Tim Frost at 384-3781 for the requirements for the fire sprinkler permits needed to extend the fire protection system into the new cooler space. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department.**TLW**
|