Permit Information
Permit NumberBLD14-01654
StatusFinaled
Name WILSON KELLER DESIGN BUILD INC
Site Address 1713 W BROADWAY AVE
Project Name 
Customer NumberBLD14-01653
ePlanReviewNo
Description
(1ST STORY COMMERCIAL SHELL) (6-7-19 PLAN MODIFICATION TO RELOCATE THE ACCESSIBLE TOILET ROOM, TO CREATE A COMPLIANT LANDING ON THE INSIDE OF THE FRONT DOOR FLUSH WITH THE OUTSIDE LANDING, AND TO CONSTRUCT AN INTERIOR RAMP AT THE ELEVATION CHANGE BETWEEN THE NEW INTERIOR LANDING AND THE EXISTING INTERIOR FLOOR LEVEL. THE BROADWAY AVENUE DOOR WILL BE THE ENTRANCE ACCESSIBLE TO THE DISABLED. THE BOTTOM OF THE DOOR WILL BE EXTENDED TO THE NEW THRESHOLD.) This building does not have a fire sprinkler system. To remodel the 890 square foot 1st story of an existing 2 story building for a future retail sales tenant. This is a shell only permit. This permit does not establish a Certificate of Occupancy for any tenant. A separate tenant improvement permit is required to establish occupancy. Work is to include a restroom accessible to the disabled, a horizontal and vertical 1-hr dwelling unit separation between the 1st and 2nd story, an exterior concrete slab at the back, and a new entry at the front. The bearing conditions for the existing 2nd floor will be changed. Structural work includes concrete footings, interior columns, and new floor joists attached to existing floor joists. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/3/20199/3/20199/3/2019PPASS
DetailsDave Hannah
DOC - Permit Finaled9/3/20199/3/20199/3/2019PPASS
DetailsDave Hannah
FIRE-Final Inspection8/29/20198/29/20198/29/2019PPASS
DetailsJim Page
Previously noted items have been corrected, no fire sprinklers, no fire alarms, fire extinguisher is in pplace with a current inspection tag. Final life fire safety inspection for area of work complete.
FIRE-Final Inspection8/28/20198/29/20198/29/2019AFAIL
DetailsJim Page
Provide code compliant door hardware for west exit. Provide double key deadbolt for main entry and install signage that reads "Door to remain unlocked while building is occupied"

Ted Phone #: ###-####
BLD-Final8/15/20198/19/20198/19/2019ANR
DetailsDave Hannah
Ted Phone #: ###-####
BLD-Framing/Rough-in1/21/20151/21/20151/21/2015APASS
DetailsJim Storey
beam engineering recieved and is aproved as built.
BLD-Framing/Rough-in12/31/20141/2/20151/2/2015APART
DetailsJim Storey
meet rogeer 900 c/n to have engineer provide end bearing/ work other than that is ok per plan.
BLD-Framing/Rough-in12/31/201412/31/20141/2/2015PDEFR
DetailsJim Storey
BLD-Conference9/3/20199/3/2019 P 
DetailsAdele J Schaffeld-Griffin