Permit Information
Permit NumberBLD14-01818
StatusFinaled
Name ESI
Site Address 501 E PARKCENTER BLVD
Project NameThe District at Parkcenter
Customer NumberBLD14-01818 - BLD14-01832
ePlanReviewYes
Description
(THE DISTRICT AT PARKCENTER - CLUB BUILDING) (TOTAL OF 15 PERMITS ARE ASSOCIATED WITH THE DRAWINGS FILED UNDER THIS PERMIT IN EPLANREVIEW) (11-4-16 PLAN MODIFICATION TO ELIMINATE WHAT WAS CALLED A 2-HR FIRE WALL IN THE CLUB BUILDING AND TO PROVIDE A NON-RATED WALL INSTEAD.) (10-11-16 PLAN MODIFICATION TO RELOCATE THE ATTIC ACCESS HATCHES FOR THE IN-TOWN BUILDINGS TO THE WALLS OF THE MECHANICAL ACCESS SHAFTS, TO CREATE A BIKE STORAGE ROOM, TO CREATE A BIKE MAINTENANCE ROOM, ETC.) (9-6-16 PLAN MODIFICATION TO INSTALL FOUR (4) PULL-DOWN ATTIC ACCESS DOORS WITH LADDERS IN THE CORRIDOR CEILINGS ON THE 3RD STORY OF THE INTOWN BUILDINGS TO PROVIDE ACCESS TO THE ROOF TOP MECHANICAL EQUIPMENT. SINCE THE ACCESS "SHAFT" MAINTAINS THE CEILING MEMBRANE OF THE 1-HR ROOF-CEILING ASSEMBLY, THE DOORS ARE NOT REQUIRED TO BE TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 AS A 1-HR HORIZONTAL ASSEMBLY.) (8-9-16 PLAN MODIFICATION TO TURN THE FORMER JANITOR’S CLOSET IN THE FITNESS BUILDING TO A POOL EQUIPMENT ROOM WITH DIRECT ACCESS FROM THE OUTSIDE. A STORAGE ROOM WILL BE CHANGED TO A JANITOR’S CLOSET WITH A SERVICE SINK. DRAWINGS WERE REVISED TO BE COMPATIBLE WITH THE DRAWINGS APPROVED UNDER THE SWIMMING POOL PERMIT. FOR THE CLUB BUILDING, SCUPPERS WERE REPLACED WITH ROOF PRIMARY DRAINS AND OVERFLOW DRAINS.) (3-4-16 DEFERRED SUBMITTAL OF GLU-LAM BEAM AND COLUMN DESIGN SUBMITTED) (12-14-15 PLAN MODIFICATION TO MODIFY THE STRUCTURAL DESIGN OF THE EXTERIOR WALL PARAPETS OF THE CLUB BUILDING.) This building does NOT have a fire sprinkler system. To construct a new 3,969 square foot one story building to be used as a club building for the apartment occupants on this site. Work is to include 2 restrooms accessible to the disabled, “high” and “low” drinking fountains, interior nonbearing walls, interior windows and doors, exterior windows and doors, insulated exterior walls, exterior siding, exterior manufactured stone, standing seam metal roof coverings, single ply roof coverings, continuous foam plastic insulation installed on top of the roof decks, suspended gypsum board ceilings, millwork, and finishes. Structural work includes concrete footings, concrete stem walls, concrete floor slabs on grade with thickened footings at interior bearing walls, glu-lam beams, glu-lam columns, roof trusses, roof joists, bearing walls, wood columns, wood beams, and shear walls. Special inspection is required for soils, concrete, and wood. A separate permit is required for the swimming pool and the barrier around it. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/5/20174/6/20174/6/2017APASS
DetailsJim Storey
Matt ###-####
BLD-Final3/30/20173/31/20174/5/2017ADEFR
DetailsJim Storey
Matt ###-####
BLD-Final3/22/20173/30/20173/31/2017PDEFR
DetailsJim Storey
Matt ###-####
FIRE-Final Inspection3/22/20173/29/20173/29/2017APASS
DetailsJim Page
Exit discharge to pool area is complete, final life fire safety inspection passed/complete.
BLD-Framing/Rough-in3/6/20173/7/20173/7/2017APASS
DetailsJim Storey
Corey Phone #: ###-####
FIRE-Final Inspection1/26/20171/30/20171/30/2017ACANC
DetailsJim Page
BLD-Final1/24/20171/27/20171/27/2017APASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith
FIRE-Conference1/25/20171/26/20171/26/2017PDONE
DetailsJim Page
Fire conference complete
FIRE-Final Inspection1/18/20171/20/20171/20/2017APART
DetailsJim Page
Partial final inspection for life fire safety complete, no fire sprinklers, fire alarm inspection is complete, fire extinguishers are in place with current inspection tags, knox box will be mounted in discussed location. Life safety will not be completed until pool area is complete and the life safety inspection for that permit is complete.
FIRE-Conference1/13/20171/13/20171/13/2017PDONE
DetailsJim Page
Fire conference complete
BLD-Wall cover10/25/201610/26/201610/26/2016APASS
DetailsJim Storey
Insulation inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith truss with in 6 inches bearing aproved by truss mfg.
BLD-Framing/Rough-in10/20/201610/21/201610/21/2016APART
DetailsJim Storey
Club House Framing Phone #: ###-#### Inspection requested via web by Corey Hockersmith truss bearing at restarm/ header at hvac duct/ ok to insulate
BLD-Framing/Rough-in10/20/201610/20/201610/20/2016PNR
DetailsJim Storey
Club House Framing Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Framing/Rough-in10/17/201610/18/201610/18/2016AFAIL
DetailsJim Storey
Club House Framing Phone #: ###-#### Inspection requested via web by Corey Hockersmith c/n
BLD-Aging Inspection2/16/20162/16/20162/16/2016 NR
DetailsJim Storey
BLD-Aging Inspection2/15/20162/15/20162/16/2016 NR
DetailsJim Storey
BLD-Conference10/23/201510/23/201510/23/2015APASS
DetailsJim Storey