Description |
(THE DISTRICT AT PARKCENTER - CLUB BUILDING) (TOTAL OF 15 PERMITS ARE ASSOCIATED WITH THE DRAWINGS FILED UNDER THIS PERMIT IN EPLANREVIEW) (11-4-16 PLAN MODIFICATION TO ELIMINATE WHAT WAS CALLED A 2-HR FIRE WALL IN THE CLUB BUILDING AND TO PROVIDE A NON-RATED WALL INSTEAD.) (10-11-16 PLAN MODIFICATION TO RELOCATE THE ATTIC ACCESS HATCHES FOR THE IN-TOWN BUILDINGS TO THE WALLS OF THE MECHANICAL ACCESS SHAFTS, TO CREATE A BIKE STORAGE ROOM, TO CREATE A BIKE MAINTENANCE ROOM, ETC.) (9-6-16 PLAN MODIFICATION TO INSTALL FOUR (4) PULL-DOWN ATTIC ACCESS DOORS WITH LADDERS IN THE CORRIDOR CEILINGS ON THE 3RD STORY OF THE INTOWN BUILDINGS TO PROVIDE ACCESS TO THE ROOF TOP MECHANICAL EQUIPMENT. SINCE THE ACCESS "SHAFT" MAINTAINS THE CEILING MEMBRANE OF THE 1-HR ROOF-CEILING ASSEMBLY, THE DOORS ARE NOT REQUIRED TO BE TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 AS A 1-HR HORIZONTAL ASSEMBLY.) (8-9-16 PLAN MODIFICATION TO TURN THE FORMER JANITOR’S CLOSET IN THE FITNESS BUILDING TO A POOL EQUIPMENT ROOM WITH DIRECT ACCESS FROM THE OUTSIDE. A STORAGE ROOM WILL BE CHANGED TO A JANITOR’S CLOSET WITH A SERVICE SINK. DRAWINGS WERE REVISED TO BE COMPATIBLE WITH THE DRAWINGS APPROVED UNDER THE SWIMMING POOL PERMIT. FOR THE CLUB BUILDING, SCUPPERS WERE REPLACED WITH ROOF PRIMARY DRAINS AND OVERFLOW DRAINS.) (3-4-16 DEFERRED SUBMITTAL OF GLU-LAM BEAM AND COLUMN DESIGN SUBMITTED) (12-14-15 PLAN MODIFICATION TO MODIFY THE STRUCTURAL DESIGN OF THE EXTERIOR WALL PARAPETS OF THE CLUB BUILDING.) This building does NOT have a fire sprinkler system. To construct a new 3,969 square foot one story building to be used as a club building for the apartment occupants on this site. Work is to include 2 restrooms accessible to the disabled, “high” and “low” drinking fountains, interior nonbearing walls, interior windows and doors, exterior windows and doors, insulated exterior walls, exterior siding, exterior manufactured stone, standing seam metal roof coverings, single ply roof coverings, continuous foam plastic insulation installed on top of the roof decks, suspended gypsum board ceilings, millwork, and finishes. Structural work includes concrete footings, concrete stem walls, concrete floor slabs on grade with thickened footings at interior bearing walls, glu-lam beams, glu-lam columns, roof trusses, roof joists, bearing walls, wood columns, wood beams, and shear walls. Special inspection is required for soils, concrete, and wood. A separate permit is required for the swimming pool and the barrier around it. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
|