Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberBLD14-02350
StatusFinaled
Name VAN AUKER CONSTRUCTION
Site Address 12324 W EXECUTIVE DR
Project NameAdvanced Hardware Supply Inc
Customer Number 
ePlanReviewNo
Description
Advanced Hardware Supply - To construct a new 28,130 square foot, one story warehouse with a 2,160 sq. ft. storage mezzanine. There will be 2,160 square feet of accessory office and retail space. This new building is constructed of concrete tilt-up exterior walls with steel interior structural frame, steel roof joists and metal roof deck. This building is fully fire sprinklered. The sprinklers are used for are increase. All construction per the approved plans and attached comment list. JCM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/20/20154/21/20154/21/2015APASS
DetailsMike Jordan
Jim Phone #: ###-####. Ok for perm occ.
FIRE-Final Inspection4/20/20154/21/20154/21/2015APASS
DetailsTroy Cobbley
Life safety passed
BLD-Final4/15/20154/20/20154/20/2015PNR
DetailsMike Jordan
Ron Phone #: ###-####
FIRE-Final Inspection4/15/20154/20/20154/20/2015AFAIL
DetailsTroy Cobbley
Life safety ok to pass when the project related fire sprinkler and fire alarm permits are passed.
BLD-Framing/Rough-in3/31/20154/1/20154/1/2015PCANC
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Ceiling Grid Inspection3/31/20154/1/20154/1/2015PPASS
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Framing/Rough-in3/26/20153/30/20153/30/2015APASS
DetailsMike Jordan
Jim Phone #: ###-####. Exterior soffit ok.
BLD-Energy code compliance3/12/20153/13/20153/13/2015APASS
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Energy code compliance3/10/20153/10/20153/10/2015APASS
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Framing/Rough-in3/6/20153/9/20153/10/2015PPASS
DetailsMike Jordan
Jim Phone #: ###-####. Interior steel stud and wood framed walls for mezz. ok.
BLD-Framing/Rough-in3/6/20153/6/20153/6/2015PNR
DetailsPhil Shearer
Jim Phone #: ###-####
BLD-Framing/Rough-in2/26/20152/26/20152/26/2015PPASS
DetailsMike Jordan
Jim Phone #: ###-####. Interior steel stud walls at loading dock.
BLD-Framing/Rough-in2/24/20152/25/20152/25/2015APASS
DetailsMike Jordan
Jim Phone #: ###-####. Interior shear wall and decking diaphragm for interior mezz.
BLD-Framing/Rough-in2/19/20152/20/20152/20/2015PPASS
DetailsMike Jordan
Jim Phone #: ###-####. joist hangar connections to 2.x6 per red built installation details.
BLD-Foundation2/12/20152/12/20152/12/2015PPASS
DetailsJim Storey
Rebar // Jim Phone #: ###-####
BLD-Footing2/10/20152/11/20152/11/2015APASS
DetailsMike Jordan
Jim-would like mid morning if poss Phone #: ###-####. column pad footings for mezz, footing for loading dock retaining walls.
BLD-Foundation1/30/20151/30/20151/30/2015PPART
DetailsMike Jordan
Rebar // Jim Phone #: ###-####.. work in progress on reinforcement for loading dock walls. Ok pending special inspection.
BLD-Other1/28/20151/29/20151/29/2015APART
DetailsMike Jordan
Welding // Jim Phone #: ###-####. Panel to panel and beam pockets. Reviewed special inspection reports to date. All welding also inspected by special inspection.
BLD-Footing12/16/201412/18/201412/18/2014APART
DetailsMike Jordan
phone call from Jim for the change//JIm Phone #: ###-####. Work in progress on remainder of exterior footings and loading dock footings. Pending special inspection.
BLD-Footing12/15/201412/15/201412/15/2014PPASS
DetailsMike Jordan
JIm// pour time is 1pm Phone #: ###-####. Exterior footing on ridline C between grids 1.5 to 6.
BLD-Footing12/1/201412/2/201412/2/2014ADEFR
DetailsMike Jordan
Concrete tilt walls rebar - Jim Phone #: ###-####. Pending special inspection.
BLD-Foundation11/12/201411/14/201411/14/2014ACANC
DetailsMike Jordan
Jim-rebar Phone #: ###-####
BLD-Foundation11/12/201411/12/201411/12/2014PPASS
DetailsMike Jordan
Jim-rebar Phone #: ###-####. Concrete tilt panels 1 to 18 and 22 to32.
BLD-Footing10/22/201410/24/201410/24/2014PPASS
DetailsMike Jordan
Jim-as early pm as possible pour time 1:30 Phone #: ###-####. interio column pad footings ok.