Permit Information
Permit NumberBLD14-03081
StatusFinaled
Name KHI CONSTRUCION INC
Site Address 3724 S ECKERT RD
Project NameHarris Ranch Mixed Use
Customer NumberBLD14-03081, 03228, 03229
ePlanReviewYes
Description
(HARRIS RANCH MIXED USE BUILDING - BLD14-03081, BLD14-03228, AND BLD14-03229 ARE ALL ATTACHED TO CASE BLD14-03081 IN EPLANREVIEW) (11-16-16 PLAN MODIFICATION TO ADD EXHAUST DUCTS FOR RESIDENTIAL RANGE HOODS. ON THE 2ND STORY THE EXHAUST DUCTS EXTEND TO THE OUTSIDE WITHIN A NONCOMBUSTIBLE SOFFIT. ON THE 3RD STORY THE EXHAUST DUCTS EXTEND INTO THE ATTIC AND THEN INDEPENDENTLY TO THE OUTSIDE.) To construct a new 3 story mixed use building having a total floor area of about 13,251 square feet (4,342 square feet 1st story, 4,663 square feet 2nd story, and 4,246 square feet 3rd story). The 1st story will be used for future retail and/or assembly tenants. The 2nd and 3rd stories will be used for a total of 7 residential apartments (six 1 story units, three on each story, and one 2 story unit). This permit is intended to establish a Certificate of Occupancy only for the residential apartments located on the 2nd and 3rd stories. The 1st story commercial tenant spaces are required to apply for and receive their own Certificates of Occupancy before occupancy. Work is to include concrete retaining walls, concrete footings, concrete foundations, exterior concrete flat work, interior concrete slab on grade, wood stud exterior walls, wood floor systems, wood roof systems, exterior windows and doors, interior windows and doors, two 1-hr stairway enclosures, vertical and horizontal 1-hr dwelling unit separations, a 1-hr occupancy separation between the 1st and 2nd stories, .5-hr corridors on the 2nd and 3rd stories, a ladder and hatch to serve the roof, millwork, interior finishes, and exterior finishes. The work is required to comply with the approved drawings, with the plan review report, with the structural design, and with all applicable codes and ordinances. Special inspection is required for concrete, soils, and welding. The design for the engineered wood trusses and the design for the aluminum balcony and railing system are deferred submittal items. The fire sprinkler system for the entire building is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection3/13/20173/13/20173/13/2017PPASS
DetailsJim Page
Previously nited items in onference remarks have been addressed and repaired. Fire sprinkler inspection is complete, fire alarm inspection is complete, knox box is in place, fire extinguishers are mounted with current inspection tags. Final life fire safety inspection passed/complete.
BLD-Final3/9/20173/10/20173/10/2017PPASS
DetailsJim Storey
Robert Phone #: ###-#### handrails west of building ok
BLD-Conference3/8/20173/8/20173/8/2017APART
DetailsDave Hannah
needs to finish handrails on ext
FIRE-Conference3/2/20173/2/20173/2/2017PDONE
DetailsJim Page
Items needed before final life fire safety inspection: knox box needs to be installed, signage for fire alarm control panel and fire sprinkler riser room, gas piping and cpvc piping that is currently exposed in the south stairwell need to be enclosed in a hour fire rated assembly, bell needs to be installed by the fire department connection and addressing needs to be a minimum 4 inch tall numbers with and a minimum stroke width of half an inch.
FIRE-Final Inspection1/19/20171/19/20171/19/2017PCANC
DetailsJim Page
Request was for a conference, not a final inspection. Fire conference complete in regards to fire extinguisher placement.
BLD-Framing/Rough-in12/5/201612/5/201612/5/2016PPASS
DetailsPhil Shearer
Kelly Phone #: ###-####. Stairs
BLD-Energy code compliance11/18/201611/21/201611/21/2016APASS
DetailsPhil Shearer
Kevin Phone #: ###-####
BLD-Energy code compliance11/16/201611/16/201611/16/2016PPASS
DetailsPhil Shearer
Kevin// insp. on main level Phone #: ###-####. Exterior wall ok not stair ways
BLD-Framing/Rough-in11/9/201611/9/201611/9/2016PCANC
DetailsPhil Shearer
Sean Phone #: ###-####. 2ND floor sofits
ok for cover
BLD-Framing/Rough-in11/8/201611/8/201611/8/2016PFAIL
DetailsPhil Shearer
Kevin Phone #: ###-#### Need to fire tape joints and screews
BLD-Framing/Rough-in11/3/201611/4/201611/4/2016AFAIL
DetailsPhil Shearer
Kevin Phone #: ###-####
BLD-Framing/Rough-in11/2/201611/2/201611/2/2016PFAIL
DetailsPhil Shearer
Kevin-2nd floor Phone #: ###-####
BLD-Framing/Rough-in9/21/20169/21/20169/21/2016PPASS
DetailsPhil Shearer
Scott Phone #: ###-#### 2nd floor
BLD-Energy code compliance9/21/20169/21/20169/21/2016PPASS
DetailsPhil Shearer
Scott Phone #: ###-#### 2nd floor
BLD-Framing/Rough-in9/20/20169/20/20169/20/2016PPART
DetailsPhil Shearer
Scott Phone #: ###-####
BLD-Framing/Rough-in9/16/20169/16/20169/16/2016PFAIL
DetailsPhil Shearer
Scott Phone #: ###-####
BLD-Framing/Rough-in9/12/20169/13/20169/13/2016APART
DetailsPhil Shearer
Scott Phone #: ###-####. OK to isulate extrior walls
BLD-Framing/Rough-in9/12/20169/12/20169/12/2016PCANC
DetailsPhil Shearer
Scott Phone #: ###-####
BLD-Energy code compliance8/30/20168/30/20168/30/2016PPASS
DetailsPhil Shearer
Scott Phone #: ###-####. 3rd floor
BLD-Energy code compliance8/29/20168/29/20168/29/2016PPART
DetailsPhil Shearer
Scott Phone #: ###-####. 3RD floor part
BLD-Framing/Rough-in8/24/20168/25/20168/25/2016PPART
DetailsPhil Shearer
Scott Phone #: ###-####.penetrations in floor assembily. OK to insulate.
BLD-Conference8/18/20168/19/20168/19/2016ADONE
DetailsPhil Shearer
9:30
BLD-Framing/Rough-in7/18/20167/19/20167/19/2016APART
DetailsPhil Shearer
Scott Phone #: ###-#### 3RD floor needs sheetrock on rated walls and to provide listed assemblies for all penetrations.
BLD-Conference7/5/20167/6/20167/6/2016PDONE
DetailsPhil Shearer
Scott Phone #: ###-####
BLD-Wall Bracing6/21/20166/22/20166/22/2016PPASS
DetailsPhil Shearer
Scott Phone #: ###-####
BLD-Wall Bracing6/16/20166/16/20166/16/2016PPASS
DetailsPhil Shearer
Scott-Roof shear Phone #: ###-####
BLD-Aging Inspection5/26/20165/26/20165/26/2016 PEND
DetailsPhil Shearer
BLD-Aging Inspection1/13/20161/13/20161/13/2016 PASS
DetailsJim Storey
wip
BLD-Foundation8/31/20159/1/20159/1/2015APASS
DetailsJim Storey
Dane Phone #: ###-#### 7140 SW Fir Loop, Ste. 231 · Tigard, OR 97223
v: 503.620.4314 · f: 503.620.4304
www.allstructure.com
MEMORANDUM
TO: FROM:
Kevin Kelly Ryan Hardie
COMPANY: DATE:
owner 8/28/15
E-MAIL OR FAX NUMBER: TOTAL NO. OF PAGES INCLUDING COVER:
1
PHONE NUMBER: PROJECT NUMBER:
13302.00
RE: PROJECT NAME:
Special Inspection Harris Ranch Mixed-Use
COPY:
File
NOTES/COMMENTS:

Kevin,
This memo follows up on our memo of 8.26.2015 regarding waiving special inspection of the
building foundation concrete. Per section 1705.3 of the building code, a condition of waiving
foundation for concrete is that the design of the footing is based on a specified compressive f'c no
greater than 2,500 psi regardless of the copressive strength specified in the construction
documents.
The original calculations had the foundation designed for 3,000 psi. Prior to the previous memo
recommending waiving special inspection, we checked the foundation design for 2,500 psi and
found it adequate as designed. Calculations are available upon request.
Please feel free to contact me if I can be of any further assistance.
Sincerely,
Ryan Hardie, PE, SE
Principal
DIGITAL SIGNATURE
BLD-Foundation8/24/20158/25/20158/25/2015APART
DetailsJim Storey
Manuel Phone #: ###-#### c/n si required justify
BLD-Footing8/21/20158/21/20158/21/2015PPASS
DetailsPhil Shearer
Manuel Phone #: ###-####