Information based on query as of Wednesday, June 26, 2024.
Permit Information
Permit NumberBLD14-03474
StatusFinaled
Name WESTMINSTER II
Site Address 5885 N COLLISTER DR
Project Name 
Customer Number 
ePlanReviewNo
Description
**Plan modification adding a spiral stairway to the front of the house. JG** WUI Zone A, Class A roof, Permit for the construction of a new 2661 sq. ft., two story (first story 1884 sq. ft., basement is 777 sq. ft.) single family dwelling with 3 bedrooms, 3 bathrooms, approximately 826 sq. ft. of covered patio’s/porches and 1032 sq. ft. attached garage per the approved plans, plan review report and any notations. R-1B zoning and setbacks per planning. A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at 384-3946

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at 384-3946.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/21/20157/22/20157/22/2015ADONE
DetailsTony Young
Josh Phone #: ###-####
DOC - Permit Finaled7/22/20157/22/20157/22/2015PPASS
DetailsTony Young
BLD-Final7/21/20157/21/20157/21/2015PPASS
DetailsTony Young
Josh Phone #: ###-####
BLD-Final7/7/20157/7/20157/7/2015PNR
DetailsTony Young
Call 30 mins before // Josh Phone #: ###-####, need hillside
BLD-Final7/2/20157/2/20157/2/2015PNR
DetailsJim Sly
Josh Phone #: ###-####
No approval from Public Works for drainage.
BLD-Energy code compliance5/5/20155/6/20155/6/2015APASS
DetailsTony Young
Josh Phone #: ###-####
BLD-Framing/Rough-in5/5/20155/5/20155/5/2015PPASS
DetailsTony Young
Josh Phone #: ###-####,, ok to cover
BLD-Energy code compliance4/29/20154/30/20154/30/2015PFAIL
DetailsTony Young
Josh Phone #: ###-####,, correction not completed
BLD-Energy code compliance4/28/20154/29/20154/29/2015PNR
DetailsTony Young
Insulation // Josh Phone #: ###-####
BLD-Framing/Rough-in4/28/20154/29/20154/29/2015PNR
DetailsTony Young
Josh Phone #: ###-####,, correction notice not complete
BLD-Framing/Rough-in4/24/20154/27/20154/27/2015AFAIL
DetailsMike Jordan
Josh Phone #: ###-####. Nail off all simpson hangars, Nail T22 girder trus on opposite face and provide the additional cluster nailing as per truss engineering, seal all penetrations in OSB on open web floor joist for draft stop, Install all MST 48 floor to floor straps on exterior as shown on sheet A4, install the simpson DTT2 with 1/2" diameter all thread in 2 places at deck to interior floor joist with blocking for lateral. Correction notice posted. ok to insulate.
BLD-Framing/Rough-in4/23/20154/24/20154/24/2015ANR
DetailsMike Jordan
Josh Phone #: ###-####. Needs to complete airseal prior to framing inspection.
BLD-Wall Bracing4/9/20154/10/20154/10/2015APASS
DetailsPhil Shearer
Josh Phone #: ###-####
BLD-Wall Bracing4/9/20154/9/20154/9/2015PFAIL
DetailsTony Young
Josh Phone #: ###-####,, not done per plan
BLD-Wall cover4/8/20154/9/20154/9/2015ADEFR
DetailsTony Young
Josh Phone #: ###-####
BLD-Wall Bracing4/8/20154/8/20154/8/2015PFAIL
DetailsTony Young
Josh Phone #: ###-####,, not done
BLD-Foundation3/3/20153/3/20153/3/2015PPART
DetailsTony Young
Adam Phone #: ###-####,, work in progress,, ok
BLD-Wall Bracing3/3/20153/3/20153/3/2015PNR
DetailsTony Young
Adam Phone #: ###-####
BLD-Footing2/27/20152/27/20152/27/2015PPART
DetailsTony Young
Pouring at 2 - Adam Phone #: ###-####
BLD-Foundation1/30/20151/30/20151/30/2015PPART
DetailsTony Young
Wall. Pouring at 1:30 // Adam Phone #: ###-####,, lower section (9-11 ft) of rear wall ok to pour
BLD-Footing1/28/20151/28/20151/29/2015PPART
DetailsDave Hannah
Adam Phone #: ###-#### back wall ftg only
BLD-Footing1/23/20151/23/20151/23/2015PCANC
DetailsDave Hannah
Adam Phone #: ###-#### no geo tect soils signoff