Permit Information
Permit NumberBLD15-01110
StatusFinaled
Name BACH LAND AND DEVELOPMENT LLC
Site Address 7472 W SAXTON DR
Project NameThe Kensington Apartments Q
Customer NumberBLD15-01107 IN EPLAN
ePlanReview 
Description
(THE KENSINGTON APARTMENTS - BUILDING Q) The drawings are filed under BLD15-01107 in ePlanReview. The NFPA 13-R fire sprinkler system is used for occupancy and for story increase. To construct a 36,450 square foot four story apartment building (9,425 sq. ft. 1st story with four 1.a units and four 2.a units, 9,425 sq. ft. 2nd story with four 1.a units and four 2.a units, 9,425 sq. ft. 3rd story with four 1.a units and four 2.a units, and 8,175 sq. ft. 4th story with four 1.a units and four 1.b units). All ground floor units are required to comply as Type B dwelling units. No elevator is provided in this building. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud bearing walls, wood stud shear walls, fiberglass shingles, fiber-cement board siding, manufactured stone veneer, 1-hr dwelling unit separations, .5-hr minimum fire-resistance-rated corridors with 20 minute smoke- and draft-control doors, exterior exit stairways fire rated like the corridors, steel stairways with concrete treads, interior nonbearing walls, millwork, and finishes. Special Inspection is required for soils and for concrete. The roof truss design is a deferred submittal item. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13-R and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/22/20173/23/20173/24/2017PPASS
DetailsTony Young
Ed Phone #: ###-####
FIRE-Final Inspection3/22/20173/23/20173/23/2017APASS
DetailsJim Page
Previous issues with fire alarm system have been resolved, final life fire safety inspection passed/complete.
BLD-Aging Inspection3/13/20173/13/20173/14/2017 PEND
DetailsTony Young
BLD-Final1/11/20171/11/20171/11/2017PPART
DetailsTony Young
Ed Phone #: ###-####,, temp occ ok,, trades,, stairs
FIRE-Final Inspection1/11/20171/11/20171/11/2017PPART
DetailsJim Page
Partial final inspection complete for life fire safety, (TCO authorized on life fire safety per conversation with Scott Arellano) fire sprinkler inspection complete, partial completion for fire alarm system (contractor is troubleshooting sync issue on level 4, fire alarm permit will remain in issued status until issue is resolved), knox box is in place, fire extinguishers are in place with current inspection tags. Fire life safety can be finaled when FIR permit for fire alarms is complete.
BLD-Energy code compliance11/1/201611/2/201611/2/2016APASS
DetailsTony Young
1st floor; Ed Phone #: ###-####,, building Q 1st or main floor ok
BLD-Framing/Rough-in11/1/201611/1/201611/1/2016PPASS
DetailsTony Young
Ed// 1st floor Phone #: ###-####
BLD-Framing/Rough-in10/31/201611/1/201611/1/2016APART
DetailsTony Young
Ed// 1st floor Phone #: ###-####,, needs mech pass 1st,, ok to insulate unaffected areas
BLD-Energy code compliance10/28/201610/31/201610/31/2016APART
DetailsTony Young
Ed Phone #: ###-####,, 2nd floor ok
BLD-Framing/Rough-in10/28/201610/28/201610/28/2016PPART
DetailsTony Young
Ed Phone #: ###-####,, 2nd floor ok
BLD-Energy code compliance10/21/201610/24/201610/24/2016APASS
DetailsTony Young
Ed Phone #: ###-####
BLD-Framing/Rough-in10/19/201610/20/201610/20/2016APART
DetailsTony Young
3rd floor; Ed Phone #: ###-####,, corrections in paint,, ok to insulate
BLD-Energy code compliance9/20/20169/20/20169/20/2016PPASS
DetailsTony Young
Ed Phone #: ###-####,, 4th floor
BLD-Energy code compliance9/19/20169/20/20169/20/2016APART
DetailsTony Young
Ed Phone #: ###-####,, 4th floor,, ok pending fire sprinkler pass on 4th floor
BLD-Energy code compliance9/19/20169/19/20169/19/2016PNR
DetailsTony Young
Ed Phone #: ###-####,, 4th floor,, needs tenting approval on sprinklers
BLD-Framing/Rough-in9/14/20169/15/20169/15/2016APART
DetailsJim Sly
Ed// 4th floor Phone #: ###-####
Framing OK.......Told Contr. to call us so we can look at Draftstops when completed.
BLD-Energy code compliance7/13/20167/14/20167/14/2016APART
DetailsTony Young
Ed Phone #: ###-####,, building Q plumbing walls ok
BLD-Wall Bracing7/11/20167/12/20167/12/2016APASS
DetailsTony Young
Ed-interior Shear Phone #: ###-####,, interior shear ok,, work in progress,, ok
BLD-Wall Bracing7/7/20167/8/20167/8/2016APART
DetailsTony Young
Ed Phone #: ###-####,, exterior shear ok building Q
BLD-Footing4/5/20164/6/20164/6/2016APART
DetailsJim Sly
Insulation // Ed Phone #: ###-####
South 3rd of Bldg........OK pending Geo Tech special inspection, tests and approvals.
BLD-Footing3/10/20163/11/20163/11/2016APEND
DetailsTony Young
Ed Phone #: ###-####,, ok pending special inspection