Permit Information
Permit NumberBLD15-01121
StatusFinaled
Name BACH LAND AND DEVELOPMENT LLC
Site Address 7364 W SAXTON DR
Project NameThe Kensington Apartments D
Customer NumberBLD15-01118 - BLD15-01137
ePlanReview 
Description
(THE KENSINGTON APARTMENTS - BUILDING D) The drawings are filed under BLD15-01118 in ePlanReview. The NFPA 13-R fire sprinkler system is used for occupancy and for story increase. To construct a 44,518 square foot four story apartment building (11,390 sq. ft. 1st story with two 3.c units, two 3.b units, three 2.c units, and one 2.g unit, 11,390 sq. ft. 2nd story with four 3.b units, three 2.c units, and one 2.g unit, 11,390 sq. ft. 3rd story with four 3.b units, three 2.c units, and one 2.g unit, 11,390 sq. ft. 4th story with four 2.d units, three 2.c units, and one 2.g unit) An elevator is provided in this building that serves all stories. All units in this building are required to comply as Type B dwelling units. Of those Type B dwelling units, 2 will also comply as Type A units. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud bearing walls, wood stud shear walls, fiberglass shingles, fiber-cement board siding, manufactured stone veneer, a 2-hr elevator shaft, 1-hr dwelling unit separations, .5-hr minimum fire-resistance-rated corridors with 20 minute smoke- and draft-control doors, exterior exit stairways fire rated like the corridors, steel stairways with concrete treads, interior nonbearing walls, millwork, and finishes. Special Inspection is required for soils and for concrete. The roof truss design is a deferred submittal item. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13-R and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection1/4/20181/5/20181/5/2018APASS
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags. Final life fire safety inspection complete.
FIRE-Final Inspection1/3/20181/4/20181/4/2018AFAIL
DetailsJim Page
Modifications required for audio/visual devices on fire alarm system in apartment restrooms that are ADA compliant, when fire alarm modifications are complete then permit can be finaled for life fire safety.
BLD-Final1/3/20181/4/20181/4/2018APASS
DetailsJim Sly
Ed Phone #: ###-####
Structural final.......OK.
BLD-Final1/3/20181/3/20181/3/2018PNR
DetailsTony Young
Ed Phone #: ###-####
BLD-Energy code compliance10/23/201710/24/201710/24/2017APASS
DetailsTony Young
1st floor // Ed Phone #: ###-####,, ok pending trades
BLD-Wall cover10/23/201710/23/201710/24/2017PPART
DetailsTony Young
1st floor // Ed Phone #: ###-####
BLD-Conference10/20/201710/20/201710/21/2017PDONE
DetailsTony Young
1st floor Fire Clucking- ED Phone #: ###-####
BLD-Framing/Rough-in10/19/201710/19/201710/20/2017PPASS
DetailsTony Young
1st floor- ED Phone #: ###-####
BLD-Other10/19/201710/19/201710/20/2017PPART
DetailsTony Young
1st floor Fire Clucking- ED Phone #: ###-####,,, needs to fix a couple spot
BLD-Energy code compliance10/3/201710/4/201710/4/2017APASS
DetailsMike Jordan
Ed Phone #: ###-####. 2nd. floor, eight units ok.
BLD-Other10/2/201710/3/201710/3/2017APART
DetailsJim Sly
Ed-fire caulking Phone #: ###-####
8 Units
BLD-Framing/Rough-in10/2/201710/3/201710/3/2017APART
DetailsJim Sly
Ed Phone #: ###-####
8 units
BLD-Energy code compliance9/6/20179/7/20179/8/2017PPASS
DetailsTony Young
3rd floor... insulation // Ed Phone #: ###-####
BLD-Framing/Rough-in9/6/20179/6/20179/6/2017PPASS
DetailsTony Young
3rd floor // Ed Phone #: ###-####
BLD-Other9/6/20179/6/20179/6/2017PPASS
DetailsTony Young
3rd floor... fire colcking // Ed Phone #: ###-####
BLD-Energy code compliance9/6/20179/6/20179/6/2017PPART
DetailsTony Young
3rd floor... insulation // Ed Phone #: ###-####,, south side units ok
BLD-Framing/Rough-in8/25/20178/28/20178/28/2017APART
DetailsTony Young
Floors 1 and 2 // Ed Phone #: ###-####,, prerock areas ok
BLD-Energy code compliance8/24/20178/25/20178/25/2017PNR
DetailsTony Young
Floors 1 and 2 // Ed Phone #: ###-####
BLD-Energy code compliance8/23/20178/23/20178/23/2017PPART
DetailsTony Young
3rd floor // Ed Phone #: ###-####,, ceiling pre-rock ok
BLD-Framing/Rough-in8/21/20178/21/20178/21/2017PPART
DetailsBrandon Shaw
Framing and fire caulkings on 1st floor
OK to insulate
BLD-Other8/21/20178/21/20178/21/2017PPART
DetailsBrandon Shaw
Framing and fire caulkings on 1st floor
BLD-Framing/Rough-in8/18/20178/18/20178/18/2017PPASS
DetailsJim Sly
barry-framing and fire caulk-2nd and 3rd floor Phone #: ###-####
BLD-Framing/Rough-in8/15/20178/15/20178/15/2017PPART
DetailsTony Young
Berry Phone #: ###-#### ,, insulation behind tubs/shower areas ok after fireblocking plate lines
BLD-Energy code compliance8/14/20178/15/20178/15/2017APASS
DetailsTony Young
Ed 4th floor insulation Phone #: ###-####
BLD-Energy code compliance8/14/20178/14/20178/14/2017PNR
DetailsTony Young
Ed 4th floor insulation Phone #: ###-####,, needs sprinkler passed 1st
BLD-Energy code compliance8/11/20178/14/20178/14/2017ANR
DetailsTony Young
Ed Phone #: ###-####, 4th floor
BLD-Framing/Rough-in8/11/20178/11/20178/12/2017PDEFR
DetailsTony Young
Ed Phone #: ###-####
BLD-Other8/11/20178/11/20178/12/2017PDEFR
DetailsTony Young
Ed Phone #: ###-####
BLD-Wall Bracing7/31/20177/31/20178/1/2017PPASS
DetailsTony Young
Elevator shear // Ed Phone #: ###-####
BLD-Energy code compliance6/8/20176/8/20176/9/2017PPASS
DetailsTony Young
Ed-plumbing wall insulation Phone #: ###-####
BLD-Wall Bracing6/2/20176/5/20176/5/2017APART
DetailsTony Young
Ed Phone #: ###-####,, sill plates on interior for pre rock
BLD-Wall Bracing6/1/20176/1/20176/1/2017PPART
DetailsTony Young
exterior shear - Ed Phone #: ###-####, exterior only,, not breeze ways, work in progress,, ok after re-doing some areas
BLD-Footing12/29/201612/30/201612/30/2016APART
DetailsJim Storey
Ed Phone #: ###-#### ok w si
BLD-Footing12/27/201612/28/201612/28/2016APART
DetailsTony Young
Ed Phone #: ###-####, slab work,, ok pending trades,, special inspection results,, cold weather provisions in effect
BLD-Footing12/20/201612/21/201612/21/2016APEND
DetailsTony Young
Ed Phone #: ###-####,, special inspection
BLD-Footing12/7/201612/8/201612/8/2016APASS
DetailsJim Sly
Ed Phone #: ###-####
OK pending Geotech special inspections, tests and approvals.
BLD-Footing10/13/201610/14/201610/14/2016APEND
DetailsTony Young
Ed Phone #: ###-####,, special inspection reports