Permit Information
Permit NumberBLD15-01921
StatusFinaled
Name KW HOMES INC
Site Address 8813 W ARDENE ST
Project NameLinh Thu'u Temple
Customer Number 
ePlanReviewYes
Description
(LINH THU'U TEMPLE) ""MODIFICATION TO ADRESS A FOOTING/FOUNDATION FOR THE STATUE THAT WAS SHOWN ON THE PLANS"" "" PLAN MODIFICATION TO THE MECHANICAL SYSTEM "" ""PLAN MODIFICATION TO INSTALL SPRAY FOAM INSULATION ON THE UNDERSIDE OF THE ROOF SHEETING TO CREEATE A CONDITIONED ATTIC"" (ESRs ARE ATTACHED) For the construction of a new 4900 sq. ft. wood framed religious building with an associated residential unit (1740 sq. ft.) with work to include all related site work, utilities mechanical plumbing and electrical work per the approved plans and the attached engineering. This building is fully fire sprinklered because of the r occupancy. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/31/20168/31/20168/31/2016PPASS
DetailsMike Jordan
Late PM Phone #: ###-####. Ok for perm occ.
BLD-Final8/29/20168/30/20168/30/2016APART
DetailsMike Jordan
Kent Phone #: ###-####. Ok for temp occ. Vertical grab bars mmounted incorrectly.
BLD-Final8/23/20168/23/20168/23/2016PFAIL
DetailsPhil Shearer
Kent// please call before Phone #: ###-####. Missing fire door at kitchen, ADA grab bars in restrooms.
FIRE-Final Inspection8/23/20168/23/20168/23/2016APASS
DetailsTroy Cobbley
life safety passed
FIRE-Final Inspection8/19/20168/22/20168/22/2016ACANC
DetailsJim Page
Inspection request will be rescheduled for 23AUG2016 to coincide with FIR sprinkler permit final inspection.
BLD-Other6/2/20166/6/20166/6/2016APASS
DetailsMike Jordan
would like call ahead; Brian Phone #: ###-####. base layer of 5/8 type x rock for roof/ceiling assembly ok.
BLD-Framing/Rough-in6/2/20166/2/20166/2/2016PPASS
DetailsMike Jordan
Kent Phone #: ###-####
BLD-Energy code compliance5/2/20165/2/20165/2/2016PPASS
DetailsMike Jordan
would like call ahead; Kent Phone #: ###-####. Ok to sheet rock the public side only.
BLD-Energy code compliance4/19/20164/19/20164/19/2016PPEND
DetailsMike Jordan
Kent Phone #: ###-####. Energy code ok. Pending resolution of mech. issues.
BLD-Conference4/18/20164/18/20164/18/2016ADONE
DetailsMike Jordan
Went over Roof ceiling assembly with contractor.
BLD-Framing/Rough-in4/14/20164/14/20164/14/2016PPASS
DetailsMike Jordan
Kent-early if possible Phone #: ###-####. All framing issues have been resolved. Ok to insulate. Advise Kent to reschedule mech. rough in inspection and noted to him the correction notice from mech. to resubmit plans.
BLD-Conference4/7/20164/7/20164/7/2016PPEND
DetailsBill VanDegrift
needed contact number to tell contractor I left a correction notice for dampers.
BLD-Framing/Rough-in4/6/20164/7/20164/7/2016PPART
DetailsMike Jordan
would like call ahead; Kent Phone #: ###-####. Transfer showers have been replaced and our now compliant. Anchor bolts installed on interior bearing walls. Fire dampers still need to be installed on resident/living side and plate washers on exterior shear walls.
BLD-Framing/Rough-in3/2/20163/3/20163/3/2016APART
DetailsMike Jordan
would like call 30min ahead; Kent Phone #: ###-####. . ok to insulate interior walls. Transfer shower issue not yet resolved. Provide fix from enginner of record on miising anchor bolts and interior bearing walls. BAthroom vent fans in residence require fire dampers. All other issues have been resolved.
BLD-Conference2/5/20162/8/20162/8/2016ADONE
DetailsMike Jordan
BLD-Framing/Rough-in2/5/20162/5/20162/5/2016PFAIL
DetailsMike Jordan
Kent Phone #: ###-####. Provide truss enginering for framing inspection. Providte the required48 inch clearance on transfer shower from control wall. Provide membrane penetration protection on can lights. Provide additional details on how to provide continous 1hr. protection on ceiling at archway. All penetrating items through the double top plates shall be protected with an approved 1hr. listed fire stop. Correction notice posted.
BLD-Framing/Rough-in12/29/201512/29/201512/29/2015PNR
DetailsMike Jordan
Kent Phone #: ###-####. Needs sprinkler rough in inspection.
BLD-Wall Bracing11/12/201511/12/201511/12/2015PPASS
DetailsMike Jordan
Kent Phone #: ###-####. Exterior shear walls only ok.
BLD-Conference11/10/201511/12/201511/12/2015APART
DetailsMike Jordan
Ken Phone #: ###-####. Ok to set windows. No approved plans on site. contractor to recall inspection.
BLD-Footing10/29/201510/30/201510/30/2015APASS
DetailsMike Jordan
Jerry Phone #: ###-####
BLD-Energy code compliance9/23/20159/24/20159/24/2015APASS
DetailsMike Jordan
Insultaion // Rob Phone #: ###-####. Rigid insulation ok. Contacted rob to let him know that there is vegetation on interior portion of pad that will need to bo removed prior to backfilling.
BLD-Foundation9/21/20159/22/20159/22/2015PPASS
DetailsMike Jordan
Jerry Phone #: ###-####
BLD-Footing9/18/20159/21/20159/21/2015PPASS
DetailsMike Jordan
Jerry Phone #: ###-####
BLD-Conference9/16/20159/17/20159/17/2015ADONE
DetailsMike Jordan
Jerry Phone #: ###-####