Permit Information
Permit NumberBLD15-03621
StatusFinaled
Name VECTOR CONSTRUCTORS LLC
Site Address 918 W IDAHO ST
Project NameAthlos Academies
Customer Number 
ePlanReviewYes
Description
**Project Management-Ron Hill**(ATHLOS ACADEMIES – STRUCTURAL UPGRADE) (DRH15-00410) (1-14-16 PLAN MODIFICATION TO INSTALL NEW STEEL BEAMS BELOW THE FLOOR BETWEEN THE 2ND AND 3RD STORIES TO REDIRECT THE GRAVITY LOAD PATH SO THAT EXISTING COLUMNS CAN BE REMOVED. THE NEW BEAMS WILL BE SUPPORTED BY NEW STEEL COLUMNS, NEW CONCRETE SHEAR WALLS, CONCRETE COLUMNS, AND CONCRETE FOOTINGS. WORK WILL ALSO INCLUDE RECONSTRUCTING PORTIONS OF THE 1ST STORY FLOOR SYSTEMS AT THE WEST AND SOUTH ENTRANCES TO MAKE A GRADUAL TRANSITION BETWEEN THE INTERIOR FLOOR LEVEL AND THE EXTERIOR SIDEWALKS.) The fire sprinkler system is used for building area and story increase. To structurally upgrade and remodel an existing building. This permit is Phase I of a multi-phase project. This permit is not intended to establish a Certificate of Occupancy for any tenant. This building has a total floor area of about 86,011 square feet, 109,511 square feet including the basement, and 113,921 square feet including the basement and the occupied roof (23,500 square foot basement, 22,917 square foot 1st story, 7,145 square foot 1st story mezzanine, 23,810 square foot 2nd story, 23,809 square foot 3rd story, 8,330 square foot 4th story, and potentially 4,410 square foot of occupied roof area at the 4th story floor level). Work is to include concrete footings, steel columns, a seismic upgrade (concrete moment frames, masonry shear walls, steel stud shear walls, new floor diaphragm over existing, wall ties, connections, etc.), filling in existing floor openings (joists, sheathing, etc.), a new masonry stairway enclosure, increasing the height of an existing concrete stairway enclosure, increasing the height of existing concrete elevator shafts, converting the basement to a parking garage, a concrete vehicular ramp with retaining walls, and new roof top insulation with a single-ply roof membrane. Special Inspection is required for concrete, concrete moment frames, masonry, steel, structural steel, welding, soils, wood diaphragm nailing, and epoxy anchors. The work is required to comply with the approved drawings, with the plan review report, with the structural design, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/12/20179/12/20179/12/2017PDONE
DetailsDave Hannah
Christina Phone #: ###-####
FIRE-Final Inspection6/27/20176/27/20176/27/2017PCANC
DetailsJim Page
Duplicate inspection request.
FIRE-Final Inspection6/27/20176/27/20176/27/2017PPASS
DetailsJim Page
Final life fire safety inspection for this permit passed/complete
BLD-Final3/28/20173/29/20173/30/2017APEND
DetailsDave Hannah
Want to walk with Dave to see if we can close out this permit as work has been done for some time Phone #: ###-#### Inspection requested via web by Joel Halfhill
BLD-Wall cover6/15/20166/17/20166/17/2016APART
DetailsDave Hannah
Shear // Joel Phone #: ###-#### ext penthouse ok to cover
BLD-Framing/Rough-in6/15/20166/17/20166/17/2016APART
DetailsDave Hannah
Joel Phone #: ###-#### ext penthouse
BLD-Other6/2/20166/3/20166/14/2016APART
DetailsDave Hannah
Joel// roof Phone #: ###-#### south side parapet
BLD-Wall Bracing5/27/20165/31/20166/1/2016PPART
DetailsDave Hannah
Joel Phone #: ###-#### pareppit along 10th street ok
BLD-Framing/Rough-in4/14/20164/14/20164/15/2016PPEND
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Billy Williams
BLD-Framing/Rough-in3/21/20163/21/20163/24/2016PPART
DetailsDave Hannah
Rough framing inspection and dicuss other inspections for other trades. Phone #: ###-#### Inspection requested via web by Billy Williams. I walked project with contractor looked at floor framing and floor sheeting nailing top floor
BLD-Conference3/6/20163/7/20163/8/2016PPASS
DetailsDave Hannah
CMU and rebar inspection. Review Exterior plans and permit. Schedule an onsite inspection for 3-15-16 with City Inspector and Fire Department for Gurny Access to Elevator. Phone #: ###-#### Inspection requested via web by Billy Williams
BLD-Footing2/3/20162/4/20162/6/2016PPEND
DetailsDave Hannah
Footing inspection in basement ladder access on site. Phone #: ###-#### Inspection requested via web by Billy Williams ok after spec/insp oks
BLD-Conference2/2/20162/3/20162/3/2016ADONE
DetailsDave Hannah
Discuss elevators and gurny access Phone #: ###-#### Inspection requested via web by Billy Williams
BLD-Conference1/5/20161/6/20161/6/2016ADONE
DetailsDave Hannah
Bill Phone #: ###-####
BLD-Wall Bracing1/5/20161/5/20161/5/2016PNR
DetailsDave Hannah
Bill Phone #: ###-####
BLD-Conference12/10/201512/11/201512/11/2015ADONE
DetailsDave Hannah
Would like to have a short meeting before we move forward with construction. Thanks Bill Williams Phone #: ###-#### Inspection requested via web by Billy Williams