Permit Information
Permit NumberBLD15-04501
StatusFinaled
Name WRIGHT BROTHERS THE BLDG CO EAGLE
Site Address 1401 S ROBERT ST
Project NameWells Fargo Boise Center
Customer Number 
ePlanReviewYes
Description
(WELLS FARGO BOISE CENTER) Plan Modification 2 – at the basement area select nonbearing walls to create a IDE room, new ductless ac system in IDE room, relocate light fixture, some electrical work and refinish the training room area. JG 4-14-16 // Plan Modification 1 - walls near elevator lobby on 1st floor revised to 1-hour corridor rating, smoke dampers required on ducts penetrating shaft wall at corridor, enclosing shaft with 1-hour rating in basement, at shaft fire dampers required where duct penetrates basement rated wall and where ducts passes 1st floor ceiling. JG 3-28-16// Permit To remodel 582 sq. ft. of an existing bank service center office entry space on the main floor in an existing building with two stories and a basement. Approval is contingent upon adhering to the approved plans on file. Work is to include: removal of select; interior brick wall, select wall, exterior storefront door and glazing, entry column, acoustic ceiling and elevator smoke doors, construction of new select; interior nonbearing walls, storefront double doors, storefront windows, acoustic ceiling, entry columns, above entry cornice, light fixtures, electrical work, mechanical duct work and interior finishes in compliance with Ch. 8 of the 2012 IBC. NOTE: This building is fire sprinklered in the basement only. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/21/20166/22/20166/22/2016PPASS
DetailsJim Storey
Kevin Phone #: ###-####
DOC - Permit Finaled6/22/20166/22/20166/22/2016PPASS
DetailsJim Storey
FIRE-Final Inspection6/21/20166/22/20166/22/2016APASS
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags. Final life fire safety inspection passed/complete.
FIRE-Final Inspection6/15/20166/16/20166/16/2016ACANC
DetailsTroy Cobbley
Need project related fire alarm permit addressed prior to a life safety inspection. I did note that atleast one fire extinguisher was expired.
BLD-Ceiling Grid Inspection5/20/20165/23/20165/23/2016APART
DetailsJim Storey
Kevin Phone #: ###-#### pending mech
BLD-Ceiling Grid Inspection5/20/20165/20/20165/20/2016PDEFR
DetailsJim Storey
Kevin Phone #: ###-#### out of time
BLD-Framing/Rough-in5/11/20165/11/20165/11/2016PPASS
DetailsJim Storey
Kevin Phone #: ###-#### walls ok
BLD-Framing/Rough-in5/10/20165/10/20165/10/2016PPASS
DetailsJim Storey
Kevin Phone #: ###-#### shaft bottom ok to cover
BLD-Framing/Rough-in4/22/20164/22/20164/22/2016PPASS
DetailsJim Storey
Kevin Phone #: ###-####
BLD-Framing/Rough-in2/22/20162/23/20162/23/2016APART
DetailsJim Storey
Partial framing, exterior only - Kevin Phone #: ###-#### extreior ft and faming ok to cover// interior arch to field review unproteced chase at east entry for shaft requriments and submit to planreview.