BLD-Final | 10/6/2017 | 10/9/2017 | 10/9/2017 | A | PASS |
Jim Sly
|
|
|
Ron Phone #: ###-#### OK for Perm Occ.
|
BLD-Final | 8/16/2017 | 8/17/2017 | 8/17/2017 | A | PART |
Jim Sly
|
|
|
Ron Phone #: ###-#### OK for Temp Occ. OK for Perm Occ when Zoning signs Perm.
|
BLD-Final | 8/11/2017 | 8/14/2017 | 8/14/2017 | P | CANC |
Jim Sly
|
|
|
Please check zoning signed off for temp too // Ron Phone #: ###-#### // called 10:10am 8-14-2017 Ron
|
FIRE-Final Inspection | 8/9/2017 | 8/9/2017 | 8/9/2017 | P | PASS |
Troy Cobbley
|
|
|
life safety passed. No gates/fence has been installed betwee building 1 and 2
|
BLD-Conference | 7/19/2017 | 7/20/2017 | 7/20/2017 | A | DONE |
Jim Sly
|
|
|
Ron Phone #: ###-####
|
BLD-Framing/Rough-in | 5/31/2017 | 6/1/2017 | 6/1/2017 | A | CANC |
Jim Sly
|
|
|
Ron-inspection is for the front of building amd canopy not for the plan modification Phone #: ###-####
|
BLD-Framing/Rough-in | 5/31/2017 | 6/1/2017 | 6/1/2017 | A | PASS |
Jim Sly
|
|
|
Ron-inspection is for the front of building amd canopy not for the plan modification Phone #: ###-#### East end Canopy on South wing framing....OK.
|
BLD-Energy code compliance | 5/12/2017 | 5/15/2017 | 5/15/2017 | A | PASS |
Jim Sly
|
|
|
Ron-bldg 1-Ron says plan mod doens''t have anything to do withg the frame or energy Phone #: ###-####
|
BLD-Framing/Rough-in | 5/12/2017 | 5/15/2017 | 5/15/2017 | A | PASS |
Jim Sly
|
|
|
Ron-bldg 1-Ron says plan mod doens''t have anything to do withg the frame or energy Phone #: ###-####
|
BLD-Energy code compliance | 5/5/2017 | 5/8/2017 | 5/8/2017 | P | PART |
Jim Sly
|
|
|
Ron Phone #: ###-#### West Wing.......OK.
|
BLD-Framing/Rough-in | 5/5/2017 | 5/8/2017 | 5/8/2017 | P | PART |
Jim Sly
|
|
|
Ron Phone #: ###-#### West Wing Framing Shear Walls and Energy Code.......OK.
|
BLD-Footing | 4/28/2017 | 5/2/2017 | 5/2/2017 | A | PART |
Jim Sly
|
|
|
Ron Wood Phone #: ###-#### Footings for Entry.......S.E. corner of complex OK pending MTI special insp, tests and approvals.
|
BLD-Energy code compliance | 4/20/2017 | 4/21/2017 | 4/21/2017 | P | PASS |
Jim Sly
|
|
|
Insulation // Ron Phone #: ###-#### Engineer Provided Engineering for above and below braced wall line......Steel studs OK and and all framing OK per engineering....South wing.
|
BLD-Framing/Rough-in | 4/14/2017 | 4/17/2017 | 4/17/2017 | A | PART |
Mike Jordan
|
|
|
partial framing (n/a plan mod scope)// Ron Wood Phone #: ###-####. South wing framing only. ok to cover walls except for interior shear walls. Contractor needs additional details. Interior shear walls constructed of steel studs in leiu of wood studs. Needs to provide connections to underfloor as shown or provide alternate from engineer. Will also need additional detail for mech. ducts through CMU wall.
|