Permit Information
Permit NumberBLD16-00159
StatusFinaled
Name SECON LLC
Site Address 8017 W FAIRVIEW AVE
Project NameLa Ranchera Market
Customer Number 
ePlanReviewYes
Description
(LA RANCHERO MARKET – NORTH END OF BUILDING) (5-3-16 PLAN MODIFICATION TO MODIFY SOME UNDER SLAB PLUMBING) (2-25-16 PLAN MODIFICATION TO INSTALL AN EJECTOR PUMP AND SUMP) The fire sprinkler system is used for unlimited area of the building. To convert an existing 2,495 square foot tenant space and remodel it for a new market/dining/food preparation tenant. Work is to include interior nonbearing walls, 2 restrooms accessible to the disabled, a “high” and a “low” drinking fountain, a double leaf exterior exit door, a Type I grease hood, a grease trap, kitchen equipment, millwork, and interior finishes. A new exterior doorway will be created in an existing masonry wall. A new steel header will be installed above the doorway. A new exterior door will be installed in the new doorway. Special Inspection is required for masonry anchors. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 as regulated by the Fire Department. A separate fire sprinkler permit shall be obtained prior to beginning any modification or installation work on such system. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/24/20165/24/20165/24/2016PPASS
DetailsMike Jordan
Ok for perm occ.
BLD-Framing/Rough-in5/23/20165/24/20165/24/2016ANR
DetailsMike Jordan
Call half hour before to meet // Fransico Phone #: ###-####. moved to pm.
FIRE-Final Inspection5/20/20165/20/20165/20/2016PPASS
DetailsTroy Cobbley
Life safety passed
FIRE-Final Inspection5/19/20165/20/20165/20/2016AFAIL
DetailsTroy Cobbley
Missing a sprinkler canopy and the ceiling in the closet near the restrooms.
BLD-Framing/Rough-in3/24/20163/24/20163/24/2016PPASS
DetailsMike Jordan
Fransisco Phone #: ###-####. All framing issues resolved. Ok to sheet rock.
BLD-Framing/Rough-in3/23/20163/24/20163/24/2016AFAIL
DetailsMike Jordan
Francasca Phone #: ###-####. Remove screws from top track of steel stud walls and provide support from structure above. Provide backing for vertical grab bars in new ADA restrooms. A correction notice was issued.
BLD-Framing/Rough-in3/21/20163/22/20163/22/2016PNR
DetailsMike Jordan
Francisco Phone #: ###-####. Needs electrical rough in inspection first.