Permit Information
Permit NumberBLD16-00727
StatusFinaled
Name DEBELLOY CONSTRUCTION
Site Address 777 W MAIN ST Unit: 115
Project NameGyro Shack
Customer Number 
ePlanReviewYes
Description
(GYRO SHACK – CITY CENTER – 1ST STORY – SUITE 115) (8-29-16 PLAN MODIFICATION TO REVISE THE MECHANICAL LAYOUT ON THE ROOF.) The fire sprinkler system is used to comply with high-rise requirements. To construct interior tenant improvements for a restaurant tenant within a 693 square foot space (375 square foot dining room and 318 square foot kitchen) located on the 1st story of a new high-rise building. Work is to include interior nonbearing walls, interior finishes, two Type I grease hoods served by one grease duct, make-up air, kitchen equipment, interior finishes, and millwork. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. This tenant space has access to core restrooms that serve multiple tenants. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/13/201610/14/201610/14/2016APASS
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by kevin debelloy
BLD-Final10/13/201610/13/201610/13/2016PDEFR
DetailsPhil Shearer
Hardware for panic bar is being installed early afternoon Phone #: ###-#### Inspection requested via web by kevin debelloy. Out of time
FIRE-Final Inspection10/13/201610/13/201610/13/2016PPASS
DetailsJim Page
Previously noted item in regards to the northwest door hardware has been repaired, final life fire safety inspection passed/complete.
FIRE-Final Inspection10/10/201610/11/201610/11/2016PPART
DetailsJim Page
Partial final inspection for area of work complete, the west side exterior doors both have double keyed deadbolts installed, one door is allowed the double keyed deadbolt. After discussing issue with superintendent the north door is going to have single action or panic door hardware installed. Final fire sprinkler inspection is complete, final fire alarm inspection is complete, final commercial hood fire suppression system inspection is complete, class K extinguisher has a current inspection tag and will be mounted in discussed location, ABC extinguisher is mounted in a common area with a current inspection tag. Life fire safety can be signed as passed/complete after door hardware is replaced on northwest exterior exit door and verfied for proper installation/operation.
BLD-Ceiling Grid Inspection9/23/20169/26/20169/26/2016APASS
DetailsDave Hannah
Kevin Phone #: ###-####
BLD-Framing/Rough-in8/15/20168/16/20168/16/2016APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by kevin debelloy
BLD-Framing/Rough-in8/11/20168/12/20168/12/2016ANR
DetailsDave Hannah
I would like to be on site for inspection with a 30 min heads up Phone #: ###-#### Inspection requested via web by kevin debelloy needs elec rough in and fire caulking piping though floor