Permit Information
Permit NumberBLD16-01060
StatusFinaled
Name PENTALON CONSTRUCTION
Site Address 2964 E PARKCENTER BLVD
Project NameArboretum at Barber Station #3
Customer NumberBLD16-01058 & 01059
ePlanReview 
Description
(ARBORETUM AT BARBER STATION – Building #3) CLUB & MULTI FAMILY-Permit to construct a new 14,850 square foot (2) story apartment / clubhouse. The first floor is about 7,635 square feet and the second floor is 7,215 square feet. This building is fully fire sprinklered with an NFPA 13 system to comply corridor reduction requirements. Scope of work includes: construct a new concrete foundation, construction of wood frame 2 story building, installation of interior non-bearing walls and bearing walls to create 6 individual units, new plumbing, new electrical, new mechanical, new insulation, new windows, new doors, and interior finishes in compliance with Chapter 8 of the 2012 IBC. This building will be sprinklered with a fully compliant NFPA 13 system to comply corridor exceptions. **TLW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/28/20186/29/20186/29/2018APASS
DetailsJim Sly
looks like everyone has signed off but you only have a partial final
I made a mistake, and found out that Pool has a seperate permit. Scheduled inspections to get pool finaled and OK for Perm Occ on this permit.
BLD-Aging Inspection2/26/20182/26/20183/2/2018 PEND
DetailsJim Sly
BLD-Aging Inspection12/25/201712/25/201712/26/2017 DONE
DetailsBrandon Shaw
Work in progress
FIRE-Final Inspection10/25/201710/25/201710/25/2017APASS
DetailsJim Page
Life fire safety inspection complete for pool area, life fire safety inspection passed/complete for Building 3
BLD-Aging Inspection9/26/20179/26/201710/2/2017 CANC
DetailsJim Sly
BLD-Conference10/2/201710/2/201710/2/2017ACANC
DetailsJim Sly
BLD-Final7/27/20177/28/20177/28/2017APART
DetailsJim Sly
TCO for resident occupancy Phone #: ###-#### Inspection requested via web by Michael West
OK for Temp Occ. Excluding the pool and pool area.......See Fire previous inspection notes. OK for Perm Occ. when Fire and Zoning signs off for Perm and pool is inspected and passed by Fire and Structural.
FIRE-Final Inspection7/26/20177/27/20177/27/2017PPART
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags, building knox box is located by the fire sprinkler riser room. Final life fire safety inspection passed/complete for TCO requested area's (Levels 1 and 2 of clubhouse, TCO authorized for life safety for 90 days per conversation with Scott Arellano) Doors exiting to pool area will be blocked to include exit signs over the doors. Temporary fencing will remain in place around the pool area until permanent fencing is installed.
FIRE-Final Inspection7/26/20177/26/20177/26/2017PCANC
DetailsJim Page
Phone #: ###-#### >> Inspection requested via web by Michael West Inspection cancelled from web by: Michael West
BLD-Conference7/18/20177/18/20177/18/2017PCANC
DetailsJim Sly
FIRE-Final Inspection7/6/20177/6/20177/6/2017PFAIL
DetailsJim Page
Documents for building fire safety and evacuation were not available at time of inspection as per note number 3 of the Building Permit Fire Code Review (BPFCR) comments. Signage for fire department access and fire lanes not installed as per note number 6 of BPFCR. Fire extinguishers are installed in cabinets but fire extinguishers do not have current inspection tags which are required as stated in note 10 of the BPFCR. Emergency egress lighting not installed in corridor on level 1, no exit discharge lighting installed on the exterior of the building at the exit discharge landings, lighting needs installed as stated in note 19 and 20 of the BPFCR. Numerous electrical box covers missing at time of inspection, covers need to be installed and secure before final life fire safey inspection. No signage on stairwell with roof access, signage needs to be installed stating stairwell with roof access. Fire alarm inspection could not be completed, no fire alarm drawings or small documents provided at time of inspection. Concrete has not been installed for discharge landings around building for egress purposes, exit discharge sidewalks need to be in place for final life fire safety inspection. Fire sprinkler permit needs to finaled before completion of life fire safety inspection (FIR permit for fire sprinkler inspection was called in by a seperate party, not the installing contractor, installing contractor is responsible for calling in their final inspection when ready). Rooms with an A occupancy need to have maximum occupancy signs installed, no occupancy signs installed at time of inspection. Ceiling tiles used for heat collection for fire sprinklers not installed at time of inspection, ceiling tiles need to be in place for final life fire safety inspection.
BLD-Ceiling Grid Inspection7/6/20177/6/20177/6/2017APART
DetailsBrandon Shaw
Building 3, hallways, first and second floor only, OK to cover
BLD-Conference7/5/20177/6/20177/6/2017ADONE
DetailsBrandon Shaw
Talk about a TCO - Jim Phone #: ###-####
BLD-Conference6/29/20176/29/20176/29/2017PDONE
DetailsJim Sly
Mike West Phone #: ###-####
BLD-Framing/Rough-in6/24/20176/26/20176/26/2017APART
DetailsBrandon Shaw
Units 411-420
BLD-Conference6/14/20176/15/20176/15/2017ADONE
DetailsJim Sly
Conference to review Requirements to obtain a CO or TCO on the clubhouse. Phone #: ###-#### Inspection requested via web by Michael West
BLD-Framing/Rough-in5/31/20175/31/20175/31/2017PPASS
DetailsJim Sly
Level 1 soffits ready for GWB Phone #: ###-#### Inspection requested via web by Michael West
BLD-Framing/Rough-in5/10/20175/10/20175/10/2017APASS
DetailsJim Sly
Clubhouse Units 201-206 Drops. Phone #: ###-#### Inspection requested via web by Michael West
BLD-Framing/Rough-in4/28/20175/1/20175/1/2017APASS
DetailsJim Sly
Lobby and Stair towers Ready to insulate Phone #: ###-#### Inspection requested via web by Michael West
BLD-Wall cover4/21/20174/21/20174/21/2017PPASS
DetailsJim Sly
Level 1 common areas insulation for okay to install GWB. Phone #: ###-#### Inspection requested via web by Michael West
BLD-Framing/Rough-in4/13/20174/13/20174/13/2017PPASS
DetailsJim Sly
Clubhouse Level 1 framing to start insulation Phone #: ###-#### Inspection requested via web by Michael West
BLD-Energy code compliance4/6/20174/7/20174/7/2017APART
DetailsJim Sly
Units 202,204,205 and 206 and pre-rock areas at level 1. Phone #: ###-#### Inspection requested via web by Michael West
BLD-Wall cover4/4/20174/4/20174/5/2017PPART
DetailsJim Sly
Insulation at Units 201-206 for GWB to start. Phone #: ###-#### Inspection requested via web by Michael West
201 and 203 ONLY......OK
BLD-Other3/28/20173/29/20173/29/2017APASS
DetailsJim Sly
Air seal level 2 units 201-206 Phone #: ###-#### Inspection requested via web by Michael West
BLD-Framing/Rough-in3/21/20173/22/20173/22/2017PPART
DetailsJim Sly
Clubhouse level 2 units. Ready to insulate. Phone #: ###-#### Inspection requested via web by Michael West
OK to insulate 2nd floor.....
BLD-Wall cover3/14/20173/15/20173/16/2017PPART
DetailsJim Sly
Clubhouse Pre-rock level 1 Phone #: ###-#### Inspection requested via web by Michael West
Ceiling.....OK.
BLD-Framing/Rough-in3/1/20173/1/20173/1/2017APART
DetailsJim Sly
1st level hallway ceiling to pre-rock Phone #: ###-#### Inspection requested via web by Michael West
BLD-Framing/Rough-in2/22/20172/22/20172/22/2017PPART
DetailsJim Sly
Walls at bathtubs to insulate and pre-rock Phone #: ###-#### Inspection requested via web by Michael West Select walls.
BLD-Framing/Rough-in2/21/20172/22/20172/22/2017ACANC
DetailsMike Jordan
Walls at bathtubs to insulate and pre-rock Phone #: ###-#### Inspection requested via web by Michael West. Moved to pm.
BLD-Framing/Rough-in2/17/20172/21/20172/21/2017ACANC
DetailsMike Jordan
Roof Sheathing. Phone #: ###-#### Inspection requested via web by Michael West
BLD-Concrete12/2/201612/2/201612/2/2016PPASS
DetailsPhil Shearer
Slab on Grade Phone #: ###-#### Inspection requested via web by Michael West. Pending MTI inspection
BLD-Foundation10/27/201610/27/201610/27/2016APASS
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Michael West. Pending MTI inspection
BLD-Footing10/12/201610/13/201610/13/2016APEND
DetailsPhil Shearer
footings Phone #: ###-#### Inspection requested via web by Michael West. pending MTI inspection