Permit Information
Permit NumberBLD16-01265
StatusFinaled
Name ESI
Site Address 501 E PARKCENTER BLVD
Project NameThe District at Parkcenter
Customer Number 
ePlanReviewYes
Description
(THE DISTRICT AT PARKCENTER – SWIMMING POOL AND FENCED ENCLOSURE) (DRH15-00030) (3-28-17 PLAN MODIFICATION TO MODIFY THE POOL MECHANICAL ROOM LOCATED IN THE FITNESS CENTER BUILDING AND TO ADD GAS EMERGENCY SHUT OFF VALVES.) To construct an in-ground concrete swimming pool. The water surface area of the swimming pool will be about 1,494 square feet, the pool perimeter will be about 221 lineal feet, and the volume will be about 28,700 gallons. The total fenced area, excluding the landscaped areas but including the pool area, has a total area of about 7,450 square feet. Work is to include a reinforced concrete (shotcrete) swimming pool (pool walls, pool floor, footings and columns for future cabanas), concrete stairways to serve the pool, handrails, a pool lift for the disabled, and pool equipment. One accessible entry for the disabled (i.e. a pool lift) is required for the swimming pool. An accessible entry (i.e. transfer system) is also required for the tanning shelf. The permanent 20’ x 20’ cabana will be constructed under this permit. The 8’ x 8’ cabanas are considered to be furniture and are not regulated by the Building Code. A fence with 3 egress gates to enclose the swimming pool area will also be constructed under this permit. The pool is not allowed to be used until this permit is finaled. Compliance with the 2012 ISPSC is allowed in lieu of the 2012 IBC. The Club Building and the Fitness Center Building restrooms will serve the swimming pool fenced area and were constructed under permits BLD14-01818 and BLD14-01825. The swimming pool shall not be filled with water until the fence is completed. The pool shall not be used and a Certificate of Occupancy shall not be issued until the work authorized under permit BLD14-01818 (Club Building) and BLD14-01825 (Fitness Center Building) is completed and Certificates of Occupancy are issued under those permits. The work is required to comply with the approved drawings, with the plan review report, with the structural design, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/5/20174/6/20174/6/2017APASS
DetailsJim Storey
Matt ###-####
BLD-Final3/30/20173/31/20174/5/2017ADEFR
DetailsJim Storey
Matt ###-####
FIRE-Final Inspection4/5/20174/5/20174/5/2017PPASS
DetailsJim Page
Exit lights have been changed to weather proof fixtures. Final life fire safety inspection passed/complete.
BLD-Final3/22/20173/30/20173/31/2017PDEFR
DetailsJim Storey
Matt ###-####
FIRE-Final Inspection3/22/20173/29/20173/29/2017APART
DetailsJim Page
Partial final for life fire safety inspection passed/complete. Exit lights currently in place are temporary and not rated for outdoor use, exit lights rated for outdoor use are on order and will be installed when received. Life fire safety can be signed off after outdoor rated exit lights are installed and inspected.
FIRE-Conference2/1/20172/1/20172/1/2017PDONE
DetailsJim Page
Fire conference complete
BLD-Footing10/31/201610/31/201610/31/2016PNR
DetailsJim Storey
Cabana footing inspection. Please come at 4pm if possible. Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Foundation7/27/20167/28/20167/28/2016PPASS
DetailsJim Storey
Pool rebar inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Foundation7/27/20167/27/20167/27/2016PCANC
DetailsJim Storey
pool rebar inspection Phone #: ###-#### >> Inspection requested via web by Corey Hockersmith Inspection cancelled from web by: Corey Hockersmith