Permit Information
Permit NumberBLD16-01779
StatusFinaled
Name HCD INC
Site Address 17 N PHILLIPPI ST
Project NameCorson Distilling Bathroom Add
Customer Number 
ePlanReviewNo
Description
**(CORSON DISTILLING – ADA BATHROOM ADDITION)** //Plan modification to add a floorplan sheet A2 to show the existing 990 sq. ft. equipment mezzanine above the office area. 8-12-2016 JG //Plan Modification to the new ADA restroom to change door location and re-arrange plumbing fixtures. 7-1-2016 JG// Permit is to remodel an existing 11,660 sq. ft. business/warehouse tenant space within an 86,387 sq. ft. building. Approval is contingent upon adhering to the approved plans on file. Work to include: construction of select interior nonbearing walls to create an ADA accessible restroom, adding a new exterior door opening, adding a landing for new door, adding a service sink, some plumbing work, some electrical work, some mechanical and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. Note: No structural engineering was required for the new exterior door opening since the opening was in an existing exterior in-filled wall. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/21/20172/22/20172/22/2017APASS
DetailsJim Sly
Please call 30-40 minutes ahead for access - Randy Phone #: ###-####
FIRE-Final Inspection2/21/20172/21/20172/21/2017PPASS
DetailsTroy Cobbley
Life safety passed
BLD-Conference12/19/20161/20/20171/20/2017ADONE
DetailsJim Sly
Call dennis Harmon ###-####. Need to check to see if Corson is still occupying space. (or go by).
No cars, no humans, no lights.........It appears that they have moved out.
BLD-Conference12/19/201612/19/201612/19/2016PPEND
DetailsJim Sly
Got ahold of Dennis Harmon....reminded him of previous correction notice pending.
BLD-Aging Inspection12/14/201612/14/201612/19/2016 CANC
DetailsJim Sly
BLD-Aging Inspection12/15/201612/15/201612/19/2016 CANC
DetailsJim Sly
BLD-Final11/18/201611/21/201611/21/2016APEND
DetailsJim Sly
Check for final. All other trades appear completed.
Issued correction notice. CN.......Complete fire corrections. call for fire final, then bldg. final.
FIRE-Final Inspection8/1/20168/2/20168/2/2016AFAIL
DetailsTroy Cobbley
Provide annual inspection for all fire extinguishers, resubmit plans showing storage and ladder access to mezzanine above the office area, a fire extinguisher is required on the mezzanine, repair the existing fire alarm system (A manual pull station has been removed from wall near office door to warehouse.
BLD-Framing/Rough-in7/21/20167/22/20167/22/2016PPASS
DetailsJim Sly
Please call Randy with results@###-#### Thanknyou Phone #: ###-#### Inspection requested via web by Dennis Harmon