Permit Information
Permit NumberBLD16-01797
StatusIssued
Name GORRINGE BROTHERS
Site Address 131 N ALLUMBAUGH ST
Project NameSARMC Behavioral Health Remode
Customer Number 
ePlanReviewYes
Description
**(SARMC BEHAVIORAL HEALTH SERVICES REMODEL)** //Plan Modification to downgrade the existing rated corridor to a nonrated corridor, quick response sprinkler heads were installed in lieu of a maintaining a 1-hour rated corridor, see attached fire sprinkler contractor letter in small documents. 3-20-2017. **JG**// Permit to remodel existing 360 sq. ft. of office space within a 21,315 sq. ft. building. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing wall, removal of select millwork, remove and replace exterior windows, construction of select new interior nonbearing walls to create (2) offices and a copy room, new millwork at copy room, new suspended acoustic ceiling, relocate existing light fixtures, electrical work, mechanical work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. Note: 1 hour rated corridor to be maintained. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection3/29/20173/30/20173/30/2017ACANC
DetailsTroy Cobbley
Paul Phone #: ###-####
BLD-Ceiling Grid Inspection7/14/20167/15/20167/15/2016APASS
DetailsJim Sly
Paul Phone #: ###-####
FIRE-Conference7/13/20167/13/20167/13/2016PDONE
DetailsTroy Cobbley
The project superintendant and I went over life safety requirements. I suggested that he employ a fire alarm contractor to see if the existing fire alarm system needs to be extended into the remodel area.
BLD-Framing/Rough-in6/28/20166/29/20166/29/2016APART
DetailsMike Jordan
Paul Phone #: ###-####. Interior steel stud framed wall ok. A correction notice was issued to correct building construction type and for the 1hr. rated corridors.