Information based on query as of Thursday, June 20, 2024.
Permit Information
Permit NumberBLD16-02492
StatusFinaled
Name THE RUSSELL CORPORATION
Site Address 5918 W STATE ST
Project NamePioneer Federal Credit Union
Customer Number 
ePlanReviewYes
Description
(PIONEER FEDERAL CREDIT UNION) Permit to construct a new 2,504 sq., ft. bank building, a detached drive thru ATM canopy and related site improvements. Scope of work includes: construction of a slab on grade concrete foundation, construction of stud framed exterior envelope walls, roof construction, construction of interior non-bearing walls to create (3) offices, a kid’s area, a lobby area, a vestibule,
(2) ADA accessible restrooms, a janitor’s closet, a break room and a PTM equipment storage room, installation of new windows and accessible doors, new acoustic ceilings, new gyp. ceilings, new roof assembly, new electrical, new mechanical, new plumbing, site work, and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. The building is not fire sprinklered. Note: Special Inspections Required see form 310. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/22/20176/22/20176/22/2017PPASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Jared Waggoner
OK for Perm Occ.
BLD-Final6/19/20176/20/20176/20/2017APEND
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Final6/16/20176/19/20176/19/2017APEND
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Final6/15/20176/16/20176/16/2017PPART
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Jared Waggoner,, temp occupancy ok,, need trades,, zoning
FIRE-Final Inspection6/15/20176/16/20176/16/2017APASS
DetailsJim Page
No fire sprinklers, in duct smoke detector is stand-alone and operational (not monitored, no other fire alarms), fire extinguisher is in place with a current inspection tag. Final life fire safety inspection passed/complete.
FIRE-Conference6/13/20176/14/20176/14/2017ADONE
DetailsJim Page
Fire conference complete
BLD-Ceiling Grid Inspection5/11/20175/12/20175/12/2017PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Energy code compliance4/6/20174/7/20174/7/2017APASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Framing/Rough-in4/5/20174/5/20174/5/2017PPASS
DetailsTony Young
Please call Jared at ###-#### 1/2 hr prior. Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Wall Bracing3/28/20173/29/20173/29/2017APASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Other3/15/20173/16/20173/16/2017PPASS
DetailsTony Young
Drive through roof nailing/ structural inspect Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Concrete3/14/20173/14/20173/14/2017APASS
DetailsTony Young
Fence CMU and Drive Through island concrete Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Framing/Rough-in3/9/20173/10/20173/11/2017APART
DetailsTony Young
Main building roof nailing Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Foundation2/27/20172/28/20172/28/2017APASS
DetailsTony Young
Trash Enclosure Foundation walls and Fence Piers Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Foundation2/23/20172/24/20172/24/2017APASS
DetailsTony Young
Drive Through Piers,Trash Enclosure footings, and fence piers/walls Phone #: ###-#### Inspection requested via web by Jared Waggoner
BLD-Footing2/21/20172/22/20172/22/2017APART
DetailsTony Young
Drive Through Footings Phone #: ###-#### Inspection requested via web by Jared Waggoner
ok pending special inspection report
BLD-Concrete2/7/20172/8/20172/8/2017PPEND
DetailsTony Young
Reinforced slab on grade at main building Phone #: ###-#### Inspection requested via web by Jared Waggoner,, ok pending special inspection results
BLD-Wall Bracing1/3/20171/3/20171/4/2017PPART
DetailsTony Young
Please call Jared 1/2 hr before inspection ###-#### Phone #: ###-#### Inspection requested via web by Jared Waggoner,, straps from headers to walls
BLD-Concrete12/15/201612/16/201612/16/2016PPART
DetailsTony Young
Please call Jared 1/2 hr prior to inspection. Reinforced slab on grade. Phone #: ###-#### Inspection requested via web by Jared Waggoner,,
pending special inspection
BLD-Foundation11/17/201611/18/201611/18/2016PPART
DetailsTony Young
Main Building Foundation walls, please call Jared 1/2 hr before inspection Phone #: ###-#### Inspection requested via web by Jared Waggoner,, ok pending special inspection
BLD-Footing11/3/201611/4/201611/4/2016PPART
DetailsTony Young
Last NE portion of main building and (2) interior footings Phone #: ###-#### Inspection requested via web by Jared Waggoner,, remainder of exterior footings ok
BLD-Footing11/1/201611/2/201611/2/2016APART
DetailsTony Young
Concrete is scheduled for 1pm. Phone #: ###-#### Inspection requested via web by Jared Waggoner,, 80% of main footings,, ok,, pending special inspection approval
FIRE-Conference9/23/20169/23/20169/23/2016ADONE
DetailsKatie Marron
Discussion with the Architect on whether a double sided monument at the corner of the intersection would suffice for building addressing on a corner lot. Based on provided site plan and site layout it should be sufficient.