BLD-Final | 6/15/2017 | 6/16/2017 | 6/16/2017 | A | PASS |
Tony Young
|
|
|
Garage access code is 0713 enter. Please call with any issues/questions. Thanks, Kim Phone #: ###-#### Inspection requested via web by Kim Winkle
|
DOC - Permit Finaled | 6/16/2017 | 6/16/2017 | 6/16/2017 | P | PASS |
Tony Young
|
|
|
c of o issued
|
BLD-Other | 3/27/2017 | 3/27/2017 | 3/27/2017 | P | PASS |
Tony Young
|
|
|
Need an inspection of the Fire Treated T;G material we are installing on a house in a WUI zone. The material has been approved by Romeo. Wanted to check and see if we need the material checked before we stain ; install? Thanks Kim Phone #: ###-#### Inspection requested via web by Kim Winkle
|
BLD-Conference | 3/1/2017 | 3/2/2017 | 3/2/2017 | P | PASS |
Tony Young
|
|
|
Need to have an Inspection on our 5/8" sheetrock soffits at 2626 N Heavens way -- only one layer needed because soffit material will be cement board. Thanks! Phone #: ###-#### Inspection requested via web by Kim Winkle,, base layer of sheet rock ok on soffit areas,, patios/porches will be alternate method
|
BLD-Energy code compliance | 2/6/2017 | 2/7/2017 | 2/7/2017 | A | PART |
Tony Young
|
|
|
Thank you! Phone #: ###-#### Inspection requested via web by Kim Winkle,, ok to cover interior,, still need sofit inspection
|
BLD-Framing/Rough-in | 1/25/2017 | 1/26/2017 | 1/26/2017 | P | FAIL |
Mike Jordan
|
|
|
Thank you! Phone #: ###-#### Inspection requested via web by Kim Winkle. NAil off all simpson hangars, fireblock al fur downs around showers and concealed areas either side of 3rd garage bay at ceiling level. Ok to insualte.
|
BLD-Conference | 12/19/2016 | 12/19/2016 | 12/19/2016 | P | PART |
Tony Young
|
|
|
Hi, need to schedule a meeting to review a ventless roof application before we proceed with needed foam application. Please call either Steve @ ###-#### or Mike @ ###-#### to schedule. Thanks Phone #: ###-#### Inspection requested via web by Kim Winkle// ok to apply spray foam on the underside of the roof deck
|
BLD-Wall Bracing | 12/14/2016 | 12/15/2016 | 12/15/2016 | P | PART |
Tony Young
|
|
|
Phone #: ###-#### Inspection requested via web by Kim Winkle,, exterior shear ok
|
BLD-Foundation | 11/7/2016 | 11/7/2016 | 11/8/2016 | P | DONE |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 11/3/2016 | 11/4/2016 | 11/4/2016 | A | PASS |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 11/2/2016 | 11/3/2016 | 11/3/2016 | P | NR |
Dave Hannah
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 10/30/2016 | 10/31/2016 | 10/31/2016 | P | NR |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 10/30/2016 | 10/31/2016 | 10/30/2016 | A | CANC |
Tony Young
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron Inspection cancelled via mobile web on Sunday, October 30, 2016.
|
BLD-Other | 10/6/2016 | 10/7/2016 | 10/7/2016 | A | PASS |
Jim Sly
|
|
|
Erosion control BMP inspection. Please call steve with any questions or concerns, 850.8424. All improvements should be done. Thank you, steve Phone #: ###-#### Inspection requested via web by steve hanson GOOD JOB!
|
BLD-Other | 10/4/2016 | 10/5/2016 | 10/5/2016 | A | FAIL |
Jim Sly
|
|
|
Site ready for EROSION CONTROL INSPECTION. Please call Steve for questions/comments/timing to arrive on site and i will meet you there. Thanks! Phone #: 208-850 -8424 Inspection requested via web by steve hanson Correction notice posted. Old waddles not effective. Re-do Re-configure add more......as required. some older riffs are actually going underneath waddles. remove sediment buildup behind waddles. Prevent sediment from reaching storm drain lid and holes......protect drain. Clean out (2) existing drain inlet filters. Install silt fence per MFGs installation instructions.
|