Permit Information
Permit NumberBLD16-02938
StatusFinaled
Name TONY TSENG
Site Address 303 N KIMBALL PL
Project NameWorld Connections
Customer Number 
ePlanReviewYes
Description
**(WORLD CONNECTIONS)** //Plan modification to construct new interior nonbearing walls to create (2) offices, a conference room, a storage room, a reception area and select new door/door frames. 1-25-2018 JG// Permit is to remodel an existing 22,124 sq. ft. building. Approval is contingent upon adhering to the approved plans on file. Work to include: construction of select interior nonbearing walls to create (2) offices, acoustic suspended ceiling, relocate light fixtures, electrical work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Ceiling Grid Inspection2/9/20182/9/20182/9/2018PPASS
DetailsMike Jordan
Adam Phone #: ###-####. OK for perm occ.
BLD-Final2/9/20182/9/20182/9/2018PPASS
DetailsMike Jordan
Ceiling grid insp on 2/9/18 was supposed to be final bldg insp. see inspectors notes in ceiling grid inspection for OK for perm occupancy
BLD-Final1/18/20181/22/20181/22/2018PPEND
DetailsMike Jordan
Adam Phone #: ###-####-no plan on site but will try and get them from the architect. Will need to architect to submit plan modifiaction to show the additional two offices that have been constructed.
FIRE-Final Inspection11/13/201711/13/201711/13/2017PPASS
DetailsTroy Cobbley
life safety passed.

Adam Phone #: ###-####
FIRE-Conference6/7/20176/12/20176/12/2017ADONE
DetailsJim Page
Fire conference complete, fire alarm modifications still need to be made to the existing system, fire sprinkler modifications have been completed, fire extinguishers are in place with current inspection tags, exit signs with discharge lighting will be installed before final inspection, exterior exits that are designated as emergency exits will also need to have exit discharge illumination installed per note number 12 on fire plan review comments.
FIRE-Final Inspection3/6/20173/6/20173/6/2017PFAIL
DetailsTroy Cobbley
No plans or small documents on site. I did a courtesy walk through with Adam. I noted the need for fire sprinkler and fire alarm modifications in several locations. It appears the emergency generator has been removed so backup power for emergency lights is an issue. Door hardware does not meet ADA on the new doors.

Leanne Phone #: ###-####