Permit Information
Permit NumberBLD16-02979
StatusFinaled
Name SHUCKLE LLC
Site Address 7655 N JENNIE LN
Project NameRiver Academy
Customer NumberESC16-01122
ePlanReviewYes
Description
(RIVER ACADAMY/EXPERT REALTY) (CUP occ load max 120 for daycare) "" PLAN MODIFICATION TO ADD A TYPE 1 HOOD"" ""PLAN MODIFICATION TO ADD A 1,500 GALLON GREASE INTERCEPTOR) Permit for the construction of a new 10,030 sq. ft. 2 story building with 8,220 sq. ft. on the first story and 1,810 sq. ft. on the second story, work to include general site and utility work and the construction of a two story wood framed structure per the approved plans and the attached engineering. The real estate office and the daycare have the same owner with the real estate office also utilized as support office space for the daycare. In the event that real-estate portion of the business is leased to an outside entity a separate C of O will be required for each entity. This building is to be fully fire sprinklered. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/18/20187/18/20187/19/2018PPASS
DetailsTony Young
need pass final for perm occ (not sure if you need to go out or not?) Steve Ellis Phone #: ###-####
BLD-Aging Inspection7/2/20187/2/20187/5/2018 PASS
DetailsTony Young
BLD-Aging Inspection4/30/20184/30/20185/1/2018 PASS
DetailsTony Young
BLD-Final4/30/20184/30/20184/30/2018PPART
DetailsTony Young
Steve Phone #: ###-####,, ok pending others
BLD-Final2/28/20183/1/20183/1/2018PPART
DetailsTony Young
still need GRD permit finaled as well as ELE Steve Phone #: ###-####,, temp. occupancy ok
FIRE-Final Inspection2/28/20183/1/20183/1/2018APASS
DetailsTroy Cobbley
Life safety passed

Steve Phone #: ###-####
FIRE-Final Inspection2/27/20182/27/20182/27/2018PFAIL
DetailsTroy Cobbley
Need the project related fire sprinkler underground and overhead permits finaled. Need the project related fire alarm permit finaled. A stand alone smoke alarm is being required to be added in the Infant room as per the Assistant Fire Marshal. A separate permit is needed for the second business located in this building. Deadbolts need to be removed. Approved hardware is needed on the Restroom Barn Doors. Fire extinguishers need to be mounted. Exit signs and emergency lights need to be tested. Small documents need to be on site. An address needs to be installed as discussed.


Steve-please call 10 minutes prior to meet-wants to go threw inspection with him Phone #: ###-####
FIRE-Conference2/23/20182/23/20182/23/2018PDONE
DetailsJim Page
Fire conference complete. Provide panic hardware on southwest exterior gate. Provide knox box by main entry. Verify door hardware is code compliant on level 2 balcony door. provide fire extinguishers throughout building. Provide correct size for address numbering.
BLD-Energy code compliance12/21/201712/21/201712/21/2017PPASS
DetailsTony Young
Steve Phone #: ###-####
BLD-Energy code compliance12/15/201712/15/201712/18/2017PPART
DetailsDave Hannah
Steve Phone #: ###-#### front office area and back two class rooms ok to cover
BLD-Framing/Rough-in12/11/201712/12/201712/12/2017APASS
DetailsDave Hannah
final framing and energy seal // Steve Ellis Phone #: ###-#### ok to insulate
BLD-Framing/Rough-in12/7/201712/7/201712/7/2017PCANC
DetailsDave Hannah
.
BLD-Framing/Rough-in12/7/201712/7/201712/7/2017PPEND
DetailsDave Hannah
needs air seal package installed needs fire blocking int shear finised do not insulate framing is ok
BLD-Framing/Rough-in11/20/201711/20/201711/22/2017PPART
DetailsDave Hannah
call 1 hr prior // framing/conference // Victor Phone #: ###-#### ok to cover shear wall at stairs
BLD-Wall Bracing9/20/20179/21/20179/21/2017PPASS
DetailsTony Young
Shear // Victor Phone #: ###-####
BLD-Wall Bracing9/19/20179/20/20179/20/2017PPART
DetailsTony Young
Shear // Victor Phone #: ###-####,, work in progress,, ok
BLD-Wall Bracing9/19/20179/19/20179/19/2017PPART
DetailsTony Young
Victor Phone #: ###-####,, work in progress, ok so far
BLD-Wall Bracing9/18/20179/19/20179/19/2017APART
DetailsTony Young
Victor Phone #: ###-####,, work in progress
BLD-Wall Bracing9/15/20179/18/20179/18/2017APART
DetailsTony Young
Victor Phone #: ###-####,, on site conf,, work in progress east side,, ok so far
BLD-Wall cover9/15/20179/15/20179/15/2017PNR
DetailsTony Young
Victor Phone #: ###-####,, walk around part,, needs too much,, re-nail and re-call
BLD-Framing/Rough-in9/15/20179/15/20179/15/2017PNR
DetailsTony Young
Victor Phone #: ###-####
BLD-Wall Bracing9/6/20179/7/20179/7/2017ACANC
DetailsJim Sly
left off piece of shear to see fire wall blocking // Victor Phone #: ###-####
BLD-Framing/Rough-in9/6/20179/7/20179/7/2017APART
DetailsJim Sly
left off piece of shear to see fire wall blocking // Victor Phone #: ###-####
Verified fireblocking in place........OK to cover 2nd story Mechanical area.......Both sides of walls.
BLD-Aging Inspection7/13/20177/13/20177/14/2017 PASS
DetailsTony Young
BLD-Aging Inspection7/12/20177/12/20177/12/2017 PEND
DetailsTony Young
BLD-Foundation2/27/20172/28/20172/28/2017APASS
DetailsTony Young
Mark-rebar-trash enclosure Phone #: ###-####,, also verified stem wall insulation,, and pier for south entry canopy
BLD-Foundation12/19/201612/20/201612/20/2016APART
DetailsTony Young
Mark Phone #: ###-####,, special inspector on site.. ok,, pending final report
BLD-Footing12/13/201612/14/201612/14/2016APART
DetailsTony Young
Mark Phone #: ###-####,, ok pending special inspection