Permit Information
Permit NumberBLD16-03500
StatusFinaled
Name AMYX SIGNATURE HOMES
Site Address 8400 W BROOKVIEW DR
Project Name8400 W Brookview Dr - Amyx
Customer Number 
ePlanReviewYes
Description
Permit for the construction of a new 2,383 sq. ft., one story single family dwelling with 4 bedrooms, 3 bathrooms, approximately 720 sq. ft. of covered patio/porch and a 1,389 sq. ft. attached garage per the approved plans, engineering, ResCheck, ACCA report and any notations. R-2 zoning and setbacks per planning.//leg ***A letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Call Jason Taylor at 384-3946

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Jason Taylor at 384-3946.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/15/20179/18/20179/18/2017APASS
DetailsMike Jordan
Troy Phone #: ###-####
DOC - Permit Finaled9/18/20179/18/20179/18/2017PPASS
DetailsMike Jordan
BLD-Aging Inspection8/30/20178/30/20178/30/2017 PASS
DetailsMike Jordan
BLD-Aging Inspection8/29/20178/29/20178/29/2017 PEND
DetailsMike Jordan
BLD-Final7/24/20177/24/20177/24/2017PCANC
DetailsMike Jordan
Temp OC- Call for acress 20 mins a head- Troy Phone #: ###-####. Stil needs public works. MAy try to post bond for public works?
BLD-Grading Inspection7/6/20177/7/20177/7/2017ACANC
DetailsMike Jordan
please ahead 30mins for access-Troy Phone #: ###-####. Spoke to troy and directed him to Brian Murphy and to Andrea Tuning for finals.
BLD-Framing/Rough-in4/14/20174/17/20174/17/2017PPASS
DetailsMike Jordan
Troy Phone #: ###-####
BLD-Energy code compliance4/13/20174/14/20174/14/2017APASS
DetailsMike Jordan
Troy Phone #: ###-####
BLD-Framing/Rough-in4/11/20174/12/20174/12/2017APART
DetailsMike Jordan
Troy Phone #: ###-####. Ok to insulate. All issues resolved. Will have interior OSB on rv bay completed on energy inspection as well As A01 truss missed interior bearing issue resolved as well.
BLD-Framing/Rough-in4/7/20174/10/20174/10/2017AFAIL
DetailsMike Jordan
Troy Phone #: ###-####. Per engineering for tall wall, block all panel edges and nail with 8d. per schedule. Provide the 2x6 diagnorl trussing as per enginering on RV bay openings. Attach sheathing on north west wall and wall adjacent to main entry. Nail off the 2ply E03 and Do3 trusses per the truss engineeing. Install the missing lateral brace on E02 truss. Install beam across mech. opening to provide the required bearing for C08, C09 and C10 trusses. Provide header over door from garage to house. Install blocking at panel edges on portal frames in back and nail. Complete nailing of all portal frames- nails only. Complete install of hold downs, missing nuts. Correction notice posted.
BLD-Foundation2/6/20172/6/20172/6/2017PPASS
DetailsDave Hannah
Ryan Phone #: ###-####
BLD-Footing2/1/20172/2/20172/2/2017PPASS
DetailsMike Jordan
Ryan Phone #: ###-####