Information based on query as of Tuesday, June 18, 2024.
Permit Information
Permit NumberBLD16-04169
StatusFinaled
Name BLEDSOE STEVE
Site Address 10165 W SARANAC DR
Project Name 
Customer Number 
ePlanReviewNo
Description
**Plan modification 12-13-16 - Adding half bath to corner of shop. Prescriptive energy code is proposed, wall heater to be installed. All work to be done according to additional plans, notes and review notes. Separate plumbing permit required. **BJM** Permit for 50'x60' (3000 square foot) detached Garage/Shop. Structure is not proposed to be heated at this time. No plumbing is proposed. Engineering has been provided for tall wall construction, lateral and structural. Special inspection is required for steel columns and welding. All work to be done according to plans, notes and local codes. **BJM**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/25/20181/26/20181/26/2018PPASS
DetailsMike Jordan
Steve Phone #: ###-####
DOC - Permit Finaled1/26/20181/26/20181/26/2018PPASS
DetailsMike Jordan
BLD-Energy code compliance8/14/20178/15/20178/15/2017APASS
DetailsMike Jordan
Steve Phone #: ###-####
BLD-Wall cover7/5/20177/5/20177/5/2017PPASS
DetailsMike Jordan
Steve Phone #: ###-####
BLD-Framing/Rough-in7/5/20177/5/20177/5/2017PPASS
DetailsMike Jordan
Steve Phone #: ###-####
BLD-Framing/Rough-in4/10/20174/11/20174/11/2017PPART
DetailsMike Jordan
Steve Phone #: ###-####
BLD-Wall Bracing4/11/20174/11/20174/11/2017PPASS
DetailsMike Jordan
Steve Phone #: ###-####
BLD-Framing/Rough-in4/6/20174/7/20174/7/2017ANR
DetailsMike Jordan
Call half hour before // Steve Phone #: ###-####
BLD-Footing3/10/20173/13/20173/13/2017APASS
DetailsMike Jordan
Interior colimn pad footings repaired. ok to place concrete.
BLD-Foundation3/8/20173/10/20173/10/2017AFAIL
DetailsMike Jordan
Phone #: ###-####. Interior column pad footings. Per approved plans and engineering, 8 #4 rebar required each way. Only 5 installed.
BLD-Footing3/8/20173/9/20173/9/2017PCANC
DetailsMike Jordan
Colton Phone #: ###-####
BLD-Energy code compliance3/9/20173/9/20173/9/2017PPASS
DetailsMike Jordan
Colton Phone #: ###-####. rigid insulation on foundation under slab on grade.
BLD-Foundation12/5/201612/6/201612/6/2016APASS
DetailsMike Jordan
Wall // Colton Phone #: ###-####
BLD-Footing12/1/201612/2/201612/2/2016PPART
DetailsMike Jordan
colton Phone #: ###-####. All issues resolved. Installing column pad rebar when on site. Ok to place concrete in footings.
BLD-Footing11/30/201612/1/201612/1/2016PFAIL
DetailsMike Jordan
Colton Phone #: ###-####. Footings not per approved plans. 3" clearance issues as well.