Information based on query as of Thursday, June 27, 2024.
Permit Information
Permit NumberBLD16-04337
StatusFinaled
Name OKLAND CONSTRUCTION CO INC
Site Address 1000 E PARK BLVD
Project NamePark Boulevard MOB
Customer Number 
ePlanReviewYes
Description
(PARK BOULEVARD MEDICAL OFFICE BUILDING – SHELL) (DRH16-00397) (5-8-17 PLAN MODIFICATION TO REVISE THE ROOF STRUCTURE ABOVE THE SOUTH TENANT SPACE TO SUPPORT AN EQUIPMENT ENCLOSURE ON THE ROOF. WORK INCLUDES RELOCATING OR ADDING INTERIOR CONCRETE FOOTINGS; ALTERATIONS TO THE COLUMNS, BEAMS, AND JOISTS OF THE ROOF STRUCTURE; PLACING A CONCRETE MECHANICAL PAD ON TOP OF THE ROOF DECK; AND CONSTRUCTING A ROOF TOP MECHANICAL EQUIPMENT SCREEN WALL.) To construct a 27,972 square foot medical office building that will likely have 2 tenants. Work is to include concrete footings, concrete stem walls (concrete slabs on grade will be placed under a future permit), steel columns, steel beams, open web steel roof joists, steel roof deck for flat roofs, prefinished metal roofing for sloping roofs, metal stud exterior walls, Sureboard Series 200 shearwall sheathing attached to metal studs, fiberglass mat sheathing on the exterior side of metal stud walls, rigid insulation installed on top of the flat roof decks, single ply roof membranes, primary roof drains and secondary roof drains, concrete roof slab within the rooftop mechanical equipment screen enclosure, rooftop mechanical equipment screen walls, Exterior Insulation and Finish System (EIFS), thin brick exterior veneer, fiber cement exterior siding, exterior windows, exterior doors, automatic sliding doors with break-outs, a suspended acoustical ceiling within the lobby, gypsum soffits within the lobby, and lobby finishes. A generator will be installed in conjunction with this permit. Special Inspection is required for soils, concrete, steel construction including welding and bolting, post installed mechanical concrete anchors, post installed epoxy concrete anchors, and perhaps EIFS. The design for the open web steel roof joists is a deferred submittal item. If this medical building will be used as an Ambulatory Care Facility where individuals are incapable of self-preservation, full compliance with 2012 IBC Section 422 is required to be shown under the future tenant improvement permit applications. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit is NOT intended to establish a Certificate of Occupancy for any tenant. Separate tenant improvement permits are required to establish occupancy. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled  1/5/2018 DONE
BLD-Final1/2/20181/3/20181/3/2018PPASS
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Jim Williams
FIRE-Final Inspection12/28/20171/2/20181/2/2018APASS
DetailsJim Page
Fire sprinkler inspection complete for core and shell, fire alarm inspection complete for core and shell, final life fire safety inspection for core and shell complete.
BLD-Final12/27/201712/28/201712/28/2017ANR
DetailsDave Hannah
Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Energy code compliance12/21/201712/21/201712/21/2017APASS
DetailsDave Hannah
Good morning Dave.
I just wanted to do an inspection on the vapor barrier in the future St Luke''s TI and also talk to you about dry walling the exterior wall in this space down to the 10'' elevation. I will be in a meeting on another project until about 10:30. Thanks
Thanks Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Framing/Rough-in9/1/20179/1/20179/1/2017APASS
DetailsDave Hannah
Periodic Framing Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Framing/Rough-in8/23/20178/24/20178/24/2017APASS
DetailsDave Hannah
Framing, periodic inspection. Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Wall cover7/27/20177/28/20177/28/2017APASS
DetailsDave Hannah
Exterior walls in ICRM TI for insulation and top down drywall. Air moisture barrier Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Framing/Rough-in6/20/20176/21/20176/21/2017APASS
DetailsDave Hannah
Exterior load bearing, shear wall and sheathing inspection Phone #: ###-#### Inspection requested via web by Jim Williams
BLD-Framing/Rough-in6/13/20176/13/20176/14/2017PPART
DetailsDave Hannah
Exterior wall framing for cover with exterior sheathing. welding header attachment etc. Phone #: ###-#### Inspection requested via web by Jim Williams screws for headers and sheer ok
BLD-Footing4/4/20174/5/20174/11/2017APASS
DetailsDave Hannah
jim Phone #: ###-####
BLD-Footing4/11/20174/11/20174/11/2017PPASS
DetailsDave Hannah
would like call ahead; Jim Phone #: ###-####