(2 PERMITS TOTAL FILED UNDER BLD16-04499 IN EPLANREVIEW) **Special inspection is requird, see form #310** Plan P-5 - Permit for the construction of a new 1415 sq. ft., two story (first story 577 sq. ft., second story 838 sq. ft.) Townhouse with 3 bedrooms, 2.5 bathrooms, and a 440 sq. ft. attached garage per the approved plans, engineering, ResCheck ACCA report and any notations. R-1C zoning and setbacks per planning. **BJM**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/19/201810/19/201810/19/2018PPASS
DetailsJim Sly
Phone #: ###-#### Inspection requested via web by Sam Brown
DOC - Permit Finaled10/19/201810/19/201810/19/2018PPASS
DetailsJim Sly
BLD-Final10/18/201810/18/201810/18/2018PFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown. Correction notice posted.
BLD-Blower Door Test Results10/18/201810/18/201810/18/2018PDONE
DetailsMike Jordan
5.7ACH @50 pa
BLD-Energy code compliance8/27/20188/27/20188/27/2018PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown
BLD-Framing/Rough-in8/27/20188/27/20188/27/2018PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown
BLD-Framing/Rough-in8/20/20188/20/20188/20/2018PFAIL
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown. Strap double top plate at 1/2 inch gas pipe penetration. Nail off simpson hangar on 2ply girder truss upsatirs. Window next to shower requied to be tempered. Ok to insulate. Correction notice posted.
BLD-Wall Bracing4/23/20184/23/20184/23/2018PPASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by Sam Brown
BLD-Aging Inspection4/4/20184/4/20184/5/2018 PASS
DetailsMike Jordan
BLD-Aging Inspection4/5/20184/5/20184/5/2018 PASS
DetailsMike Jordan
BLD-Foundation11/21/201711/21/201711/21/2017PPASS
DetailsMike Jordan
rebar // sam Phone #: ###-####. Interior thickend footings.
BLD-Foundation10/23/201710/23/201710/23/2017PPASS
DetailsMike Jordan
Sam Phone #: ###-####. Rigid insualtion on stemwall under slab on grade.
BLD-Foundation10/18/201710/18/201710/18/2017PPASS
DetailsMike Jordan
Sam Phone #: ###-####
BLD-Footing10/17/201710/17/201710/17/2017PPASS
DetailsMike Jordan
Manny Phone #: ###-####