Permit Information
Permit NumberBLD17-00566
StatusFinaled
Name SAUCERMAN CONSTRUCTION
Site Address 8400 W WESTPARK ST
Project NameCable One
Customer Number 
ePlanReviewYes
Description
(CABLE ONE – WHOLE BUILDING TENANT) (7-2-18 PLAN MODIFICATION TO CREATE A 431 SQUARE FOOT OFFICE WITH DOOR AND GLASS SIDELIGHT AND A 129 SQUARE FOOT OFFICE WITH DOOR AND INTERIOR SLIDING WINDOW WITHIN AN OPEN OFFICE AREA, TO RELOCATE DOOR 111A AND TO CUT BACK A BASE CABINET TO PROVIDE 18 INCHES ON THE PULL SIDE OF THE DOOR, TO RELOCATE DOOR 113A WHICH WOULD OTHERWISE BE IN CONFLICT WITH DOOR 111A, TO CONSTRUCT AN INTERIOR CLOSET WITH A DOUBLE LEAF DOOR, TO CONSTRUCT INTERIOR NONSTRUCTURAL WALLS, AND TO RELOCATE THE DRINKING FOUNTAINS.) (12-29-17 PLAN MODIFICATION TO INCREASE THE OCCUPANT LOAD OF “MEETING ROOM 106” FROM 69 TO 99 BASED ON THE SUBMITTED FURNITURE PLAN SHOWING 96 CHAIRS AND DIMENSIONED AISLES. WORK INCLUDES UPGRADING THE EGRESS PATH THROUGH “OPEN OFFICE 107” AND “LOBBY 102”. THE SWING OF A GATE WILL BE CHANGED TO SWING IN THE DIRECTION OF EGRESS TRAVEL AND PANIC HARDWARE WILL BE PROVIDED ON THE GATE. THUMB TURNS WILL BE REMOVED FROM EXISTING AUTOMATIC DOORS.) Phase 1 and 2-This building does not have a fire sprinkler system. To expand a meeting room to 1,032 square feet, to expand the adjacent break room to 664 square feet, to create a 233 square foot conference room, and to create miscellaneous other rooms within an existing 14,680 square foot one story office building. Work is to include interior nonbearing wall, an interior 2-hr fire-resistance-rated occupancy separation wall (fire barrier wall) with 90 minute fire doors, interior doors and windows, a storage cage made from chain link fencing, service counters, a new suspended acoustical ceiling, a gypsum board soffit, lever hardware on existing doors, millwork, and finishes. New roof top HVAC units will be installed in conjunction with this permit. The new units are not allowed to weigh more than the units they replace. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. A separate fire alarm permit shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/10/20189/11/20189/11/2018APASS
DetailsMike Jordan
Please call 30 min prior to inspection. Phone #: ###-#### Inspection requested via web by John Saucerman. the panic hardware has been installed. ok for perm occ.
BLD-Final9/6/20189/7/20189/7/2018AFAIL
DetailsMike Jordan
Please call; 30 min prior to inspection Phone #: ###-#### Inspection requested via web by John Saucerman. Provided panic hardware on the south east exit door. Everything else ok.
FIRE-Final Inspection9/6/20189/6/20189/6/2018PPASS
DetailsJim Page
No fire sprinklers, fire alarm inspection is complete (FIR17-00512), fire extinguishers are placed with current inspection tags. Final life fire safety inspection complete.

Please call 30 min prior to inspection Phone #: ###-#### Inspection requested via web by John Saucerman
BLD-Ceiling Grid Inspection7/25/20187/26/20187/26/2018APASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by John Saucerman
BLD-Framing/Rough-in6/15/20186/15/20186/15/2018PPART
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by John Saucerman. Interior steel stud framed walls ok. Needs to submit plan mod to reflect the adtional walls that have been aded.
BLD-Ceiling Grid Inspection5/7/20185/8/20185/8/2018APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by John Saucerman. Lobby area grid ok.
BLD-Ceiling Grid Inspection5/4/20185/7/20185/7/2018PCANC
DetailsMike Jordan
Ceiling grid in lobby. Phone #: ###-#### >> Inspection requested via web by Shane Treasure Inspection cancelled from web by: Shane Treasure
BLD-Ceiling Grid Inspection4/27/20184/30/20184/30/2018APASS
DetailsMike Jordan
Please call Shane at 208 954 4469 with any questions. Phone #: ###-#### Inspection requested via web by Shane Treasure
BLD-Framing/Rough-in3/15/20183/15/20183/15/2018PPASS
DetailsMike Jordan
Please call prior to inspection Phone #: ###-#### Inspection requested via web by John Saucerman. Interior steel stud framed walls only ok, phase 2A.
BLD - Request for Extension2/8/20182/9/20182/9/2018APASS
DetailsMike Jordan
Paul Phone #: ###-####
BLD-Conference2/8/20182/9/20182/8/2018ADONE
DetailsCandy A. Nichols
this is a test inspection to see if it extends to permits expiration date
BLD-Final11/14/201711/14/201711/14/2017PPART
DetailsMike Jordan
Please call 30 minutes prior to arrival for inspection Phone #: ###-#### Inspection requested via web by John Saucerman. Ok temp c of o-phase 2 will start in or about March 2018
FIRE-Final Inspection11/13/201711/14/201711/14/2017PPART
DetailsTroy Cobbley
Life safety for Phase I passed.

Please call 30 minutes prior to inspection Phone #: ###-#### Inspection requested via web by John Saucerman
FIRE-Final Inspection11/3/201711/6/201711/6/2017PFAIL
DetailsTroy Cobbley
For phase I to be passed I need exit discharge lights at the marked exits and per Carl Westfall a temporary occupant load sign of 49 for Room 106. This will allow only one exit required until the permanent exit path through phase 2 is finished

Phone #: ###-#### Inspection requested via web by John Saucerman
BLD-Ceiling Grid Inspection7/7/20177/10/20177/10/2017APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by John Saucerman
BLD-Wall cover6/2/20176/5/20176/5/2017APASS
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by John Saucerman
BLD-Wall cover5/31/20176/1/20176/1/2017PPART
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by John Saucerman. work in progress on 1st. layer, ok.
BLD-Framing/Rough-in5/30/20175/31/20175/31/2017PPART
DetailsMike Jordan
Phone #: ###-#### Inspection requested via web by John Saucerman. Interior steel stud walls for infills and new conferance rooms phase 1. provide UL listed and approved plumbing boxes for 2hr. wall.