Description |
(GRIFFIN CREEK OFFICE BUILDING – NEW BUILDING SHELL AND CORE – THREE TENANT SPACES) (DRH16-00398) This building does not have a fire sprinkler system. To construct a 5,165 square foot office building having 3 tenant spaces. Work is to include concrete footings, concrete foundations, concrete piers at perimeter columns, concrete slab on grade, tube steel columns, moment frames using wide flange beams and wide flange columns, glu-lam beams, steel roof deck, parapet braces, insulation installed on top of the roof deck, a single ply roofing membrane, primary and overflow roof drains, exterior steel stud walls with cavity and continuous insulation, 1-hr fire-resistance-rated West exterior wall and parapet due to proximity to the West property line, two uninsulated concrete exterior walls, an exterior steel awning at the building entry, exterior windows, exterior door, interior nonbearing walls, interior windows and doors, suspended acoustical ceiling, gypsum board ceilings, walnut wood ceiling, two shared toilet rooms accessible to the disabled, millwork, and finishes. Special Inspection is required for concrete, anchors post installed in hardened concrete, and structural steel (including bolting and welding). A trash enclosure will also be constructed under this permit. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit does not establish a Certificate of Occupancy for any portion of this building or for any tenant. A separate permit is required to establish a Certificate of Occupancy for each individual tenant. **CJW**
|