BLD-Final | 5/16/2018 | 5/18/2018 | 5/18/2018 | A | PASS |
Jim Storey
|
|
|
Swimming Pool Final Inspection Phone #: ###-#### Inspection requested via web by Brandy McConkey as noted
|
DOC - Permit Finaled | 5/18/2018 | 5/18/2018 | 5/18/2018 | P | PASS |
Jim Storey
|
|
|
gates anchored closed only access alarmed house barrior.
|
BLD-Final | 4/11/2018 | 4/13/2018 | 4/16/2018 | A | FAIL |
Jim Storey
|
|
|
Swimming Pool Final Inspection Phone #: ###-#### Inspection requested via web by Brandy McConkey8. Access gates shall comply with the requirements of Items 1 through 7, and shall be equipped to accommodate a locking device. Pedestrian access gates shall open outward away from the pool, and shall be self-closing and have a self-latching device. Gates, other than pedestrian access gates, shall have a self-latching device. Where the release mechanism of the self-latching device is located less than 54 inches (1372 mm) from the bottom of the gate, the release mechanism and openings shall comply with the following:
8.1. The release mechanism shall be located on the pool side of the gate at least 3 inches (76 mm) below the top of the gate; and
8.2. The gate and barrier shall have no opening larger than 1/2 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism.
|
BLD-Aging Inspection | 10/6/2017 | 10/6/2017 | 10/6/2017 | | PEND |
Jim Storey
|
|
|
ncfi/no mech
|
BLD-Foundation | 5/23/2017 | 5/24/2017 | 5/24/2017 | A | PASS |
Jim Storey
|
|
|
Brandy-steel rebar Phone #: ###-####
|