Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD17-00729
StatusFinaled
Name STEED CONSTRUCTION
Site Address 7997 W FRANKLIN RD
Project NameLongHorn Steakhouse
Customer NumberBLD17-01979 FOR DEMO
ePlanReviewYes
Description
(LONGHORN STEAKHOUSE) //Plan modification #3 to replace bar sink with a bar washer, revise the quantity of drain boards, add a dump sink to the bar area, relocate the hand sink in the bar, and associated plumbing/electrical revisions. 10-18-2017 JG// - //Plan Modification #2 – to add to go parking spaces, revised bar layout, and plumbing/mechanical/electrical modifications. 8-4-2017 JG// - //Plan modification to remove external roof ladder and replace with an internal roof ladder with a roof hatch, light fixture and mechanical ductwork relocated for new ladder location. 7-6-2017 JG// Permit to construct a new 5,593 sq., ft. assembly restaurant building and related site improvements. Scope of work includes: construction of footing foundation, slab on grade concrete floor, construction of wood stud framed exterior envelope walls, truss roof construction, construction of interior non-bearing walls to create lobby area, dining areas, bar area, commercial kitchen, walk-in cooler, office, mechanical room, storage closets and men’s and woman’s restrooms accessible to the disabled, new windows and accessible doors, new electrical, new mechanical, new plumbing, site work, and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Note: Special Inspections Required see form 310. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/11/201712/12/201712/12/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. Ok for temp. occ. Will be ok for perm occ. once zoning/public works and electrical signs perm.
FIRE-Final Inspection12/8/201712/8/201712/8/2017PPASS
DetailsTroy Cobbley
Life safety passed

Mike Phone #: ###-####
FIRE-Final Inspection12/6/201712/7/201712/7/2017PFAIL
DetailsTroy Cobbley
Life safety will be ok to sign off when the project fire alarm and fire sprinkler permits are finaled

MIke Phone #: ###-####
BLD-Ceiling Grid Inspection11/28/201711/29/201711/29/2017ADONE
DetailsMike Jordan
Mike Phone #: ###-####. Contractor provided documentation for wood ceiling smoke and flame spread values. Currently, this will not meet a lass C rating. Documentation provided for and intumescent fire retatrdent varnish to meet ASTM E-84. Falme Control No.166 wil be used to coat the wood ceiling.
BLD-Ceiling Grid Inspection11/20/201711/21/201711/21/2017PPASS
DetailsMike Jordan
###-####- Mike.
BLD-Energy code compliance10/13/201710/16/201710/16/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. Energy complete. ok to cover.
BLD-Energy code compliance10/6/201710/9/201710/9/2017APART
DetailsMike Jordan
Mike Phone #: ###-####. South and east exterior walls ok.
BLD-Framing/Rough-in10/9/201710/9/201710/9/2017APART
DetailsMike Jordan
Mike Phone #: ###-####. Wood framed walls and hardlids for restroom ok.
BLD-Framing/Rough-in10/5/201710/6/201710/6/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. Main entry and bar area.
BLD-Energy code compliance10/6/201710/6/201710/6/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. West exterior wall.
BLD-Framing/Rough-in9/28/20179/29/20179/29/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. Double top plate splice and additional studs added in overbuild. Trusses, lateral bracing and additional bracing on botom chords, all related hardware and bracing ok.
BLD-Wall Bracing9/29/20179/29/20179/29/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. North exterior shear wall ok.
BLD-Framing/Rough-in9/15/20179/18/20179/18/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. Exterior furred walls ok.
BLD-Wall Bracing9/18/20179/18/20179/18/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. South, east and west exterior shear walls ok.
BLD-Framing/Rough-in9/12/20179/12/20179/12/2017PPART
DetailsMike Jordan
Mike Phone #: ###-####. Remainder of overbuild. Needs to provide strap and double top plate splice and provide 2 additional studs under double LVL.
FIRE-Conference9/7/20179/8/20179/8/2017ADONE
DetailsTroy Cobbley
Mike and I discussed combustible concealed spaces.

Phone #: ###-####
BLD-Framing/Rough-in9/5/20179/6/20179/6/2017APASS
DetailsMike Jordan
Mike Phone #: ###-####. Roof diaphragm nailing ok. Parapet and over builds ok.
BLD-Foundation8/14/20178/15/20178/15/2017APASS
DetailsMike Jordan
Pour at 11 /// Mike Phone #: ###-####. CMU pilasters for hip roof ok.
BLD-Foundation7/14/20177/17/20177/17/2017APART
DetailsMike Jordan
Pour 11 // Mike Phone #: ###-####. Work in progress on cmu stemwall, permiter walls from top of footing to finish floor. Will have special inspection.
BLD-Footing7/6/20177/7/20177/7/2017APART
DetailsBrandon Shaw
Building foot print and columns, garbage
/recyling bin area at later time